Install A Dimm - Oracle SPARC M8 Service Manual

Hide thumbs Also See for SPARC M8:
Table of Contents

Advertisement

Install a DIMM

If you are replacing a faulty CMIOU from the chassis, remove all of
the DIMMs from the faulty CMIOU so that you can install them into the
replacement CMIOU.
Place the removed DIMMs on a grounded antistatic mat, and continue to
CMIOU" on page
Install a DIMM
Caution -
safety instructions described in
Configuration" on page
Take the necessary ESD precautions.
1.
See
"Prevent ESD Damage" on page
2.
Ensure that you have removed either the CMIOU containing the faulted DIMM or
the CMIOU filler panel.
See
"Remove a CMIOU" on page
3.
If you are replacing a faulty DIMM, ensure that you have removed it.
See
"Remove a DIMM" on page
4.
Unpack the replacement DIMM, and place it on a grounded antistatic mat.
Caution -
CMIOU.
Ensure that the ejector tabs on the connector that will receive the DIMM are in
5.
the open position.
6.
Install the DIMM.
Align the DIMM notch with the key in the connector.
a.
Caution -
is reversed.
114
SPARC M8 and SPARC M7 Servers Service Manual • September 2017
102.
Before beginning this procedure, ensure that you are familiar with the cautions and
"Safety Information" on page 57
106.
95.
112.
You must install the same size and capacity of DIMMs that are already in the existing
Ensure that the orientation is correct. The DIMM might be damaged if the orientation
61.
"Install a
and the information in
"DIMM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc m7

Table of Contents