Install a Fan Cable Assembly
3.
Screw the top bracket of the cable assembly to the chassis.
4.
Reinstall the interconnects in the same slots from which you removed them.
See
"Servicing Internal Interconnect Assemblies" on page
Interconnect Assemblies" on page 305
Interconnect Assemblies" on page
5.
Reseat the SP tray.
See
"Reseat or Install an SP Tray" on page
6.
Reseat the CMIOUs.
See
"Reseat a CMIOU" on page
7.
Reinstall the fans in the same slots from which you removed them.
See
"Install a Fan Module (CMIOU Chassis)" on page 182
Chassis)" on page
8.
Switch on the appropriate PDU circuit breakers and power on the server.
"Returning the Server to Operation" on page
9.
Verify that the fault has been cleared and the replaced component is operational.
See
"Verify That a Fault Has Been Cleared" on page
214
SPARC M8 and SPARC M7 Servers Service Manual • September 2017
(SPARC M7-16), and
285.
101.
186.
297,
"Servicing External
"Servicing SP Internal
246.
or
"Install a Fan Module (Switch
73.
54.