Oracle SPARC M8 Service Manual page 37

Hide thumbs Also See for SPARC M8:
Table of Contents

Advertisement

System
Manufacturer
: Oracle Corporation
Name
: SPARC M7-x
Part_Number
: 32397701+7+1
Serial_Number : AK00192372
----------------------------------------
Suspect 1 of 1
Fault class : fault.chassis.env.power.loss
Certainty
: 100%
Affects
: /SYS/PS9/SUPPLY
Status
: faulted
FRU
Status
Location
Manufacturer
Name
Part_Number
Revision
Serial_Number
Chassis
Manufacturer
Name
Part_Number
Serial_Number : AK00192372
Description : A power supply AC input voltage failure has occurred.
Response
: The service-required LED on the affected power supply and
chassis will be illuminated.
Impact
: Server will be powered down when there are insufficient
operational power supplies.
Action
: Please refer to the associated reference document at
http://support.oracle.com/msg/SPT-8000-5X for the latest
service procedures and policies regarding this diagnosis.
faultmgmtsp>
In this example, a fault is displayed that includes these details:
Date and time of the fault (2014-10-27/10:20:25).
UUID (18b66cdc-aa00-c614-a50f-eed199043bd7), which is unique to each fault.
: faulty
: /SYS/PS9
: Power-One, Inc.
: A261_POWER_SUPPLY
: 7068817
: 21
: 465776G+1320B2083P
: Oracle Corporation
: SPARC M7-x
: 32397701+7+1
Identify Faulted Components
Detecting and Managing Faults
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc m7

Table of Contents