Related Information
"Understanding DIMM Configurations" on page 69
■
"Understanding DIMM Configurations" on page 69
■
"Determine Which DIMM Is Faulty (DIMM Fault LEDs)" on page 76
■
"Determine Which DIMM Is Faulty (PSH)" on page 74
■
"Install a DIMM" on page 81
■
"Verify a DIMM" on page 84
■
Install a DIMM
DIMMs are cold-service components that can be replaced by customers. For the location of the
DIMMs, see
This procedure requires that you handle components that are sensitive to electrostatic
Caution -
discharge. This discharge can cause failure of server components.
1.
Consider your first steps.
Familiarize yourself with DIMM population rules.
■
See
"Understanding DIMM Configurations" on page 69
Prepare the system for service.
■
See
"Preparing for Service" on page
Remove the processor module. Place the processor module on an ESD-
■
protect work surface.
See
"Remove a Processor Module or Processor Filler Module" on page
2.
Consider your next steps.
If you are replacing a faulty DIMM, ensure that you have removed the faulty
■
DIMM.
See
"Identifying Faulty DIMMs" on page
See
"Remove a DIMM" on page
If you are adding DIMMs to a half-populated processor module:
■
"Processor Module Components" on page
18.
43.
74.
78.
Install a DIMM
60.
Servicing DIMMs
81