Troubleshooting; Power Supply Failure; Symptom; Solution - H3C RA10 Installation Manual

Hide thumbs Also See for RA10:
Table of Contents

Advertisement

Troubleshooting

IMPORTANT:
• The barcode on the router chassis contains product information that must be provided to local
sales agent when you return a faulty router for repair.
• Keep the tamper-proof seal on a mounting screw on the chassis cover intact, and if you want to
open the chassis, contact H3C for permission. Otherwise, H3C shall not be liable for any
consequence.

Power supply failure

Symptom

The router cannot be powered on and the PWR LED on the front panel is off.

Solution

To resolve the problem:
Power off the router.
1.
Verify that the router is connected to the power source correctly.
2.
Verify that the power source is operating correctly.
3.
Verify that the power cord is in good condition.
4.
If the problem persists, contact H3C Support.
5.

No display on the configuration terminal

Symptom
The configuration terminal does not have display when the router is powered on.
Solution
To resolve the problem:
Verify that the power system is operating correctly.
1.
Verify that the console cable is connected correctly and the connected serial port is the same as
2.
the port configured on the terminal.
Verify that the terminal is configured correctly:
3.
Baud rate—9,600.
Data bits—8.
Parity—None.
Stop bits—1.
Flow control—None.
Emulation—VT100.