Restricting Torque - YASKAWA SGM-A3 User Manual

Sigma series ac servomotors and driver sgm series sgmp series servomotors dr2 servopack
Table of Contents

Advertisement

If dynamic brake stop mode is selected, specify the operation to be performed when the
motor stops.
Cn-01
Cn-01
bit 7

3.1.3 Restricting Torque

1) The Servopack can provide the following torque control:
D Torque restriction
D Torque control
This section describes how to use levels 1 and 2 of the torque restriction function.
2) How to Set Level 1: Internal Torque Limit
The maximum torque is restricted to the values set in the following user constants.
Cn-08
Cn-09
Setting
0
Releases dynamic brake after the motor stops.
1
Does not release dynamic brake even after the motor stops.
Level 1: To restrict the maximum output torque to
protect the machine or workpiece
Level 2: To restrict torque after the motor moves the
machine to a specified position
Level 3: To always control output torque, not speed
Level 4: To alternately use speed control and torque
control
TLMTF
Forward Rotation
Unit:
Torque Limit
%
TLMTR
Unit:
Reverse Rotation
%
Torque Limit
3.1 Setting User Constants According to Machine Characteristics
Meaning
Setting
Factory
Range: 0 to
Setting:
Maximum
Maximum
Torque
Torque
Setting
Factory
Range: 0 to
Setting:
Maximum
Maximum
Torque
Torque
For Speed/Torque
Control and Position
Control
For Speed/Torque
Control and Position
Control
57