YASKAWA SGM-A3 User Manual page 103

Sigma series ac servomotors and driver sgm series sgmp series servomotors dr2 servopack
Table of Contents

Advertisement

APPLICATIONS OF Σ-SERIES PRODUCTS
3.2.6 Using Contact Input Speed Control cont.
3
90
4) The figure below illustrates an example of operation in contact input speed control mode.
Using the soft start function reduces physical shock at speed changeover.
When Contact Input Speed Control is Used
Motor speed
Stopped
OFF
OFF
Note For the position control, the soft start function is available only when contact input
speed control is used. The soft start function is not available when pulse reference
input is used.
For the position control type, if contact input speed control mode is switched to
pulse reference input mode when the motor is running at the 1st, 2nd or 3rd
speed, the Servopack does not receive a pulse reference until positioning com-
plete signal COIN is output.
Always start outputting a pulse reference from the host controller after a position-
ing complete signal is output from the Servopack.
Signal Generation Timing for Position Control Type
Motor speed
0 r/min
COIN
Pulse reference
N-CL
P-CL
Selected speed
1st speed
The above figure illustrates signal generation timing when the soft start function is
used.
The value of t
is not influenced by use of the soft start function.
1
A maximum of 6 ms delay occurs when P-CL or N-CL signal is read.
3rd speed
2nd speed
1st speed
Stopped
ON
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
3rd speed
2nd speed
Set acceleration and
deceleration values in Cn-07
and Cn-23 (soft start time).
1st speed
2nd speed
3rd speed
ON
ON
OFF
ON
ON
OFF
ON
Pulse reference
1st speed
Stopped
OFF