YASKAWA SGM-A3 User Manual page 40

Sigma series ac servomotors and driver sgm series sgmp series servomotors dr2 servopack
Table of Contents

Advertisement

BASIC USES OF S-SERIES PRODUCTS
Standard connection method for S-Series AC Servo Drives:
Molded-case circuit breaker (MCCB)
Used to protect power
supply line. Shuts the
circuit off when
overcurrent is detected.
Noise filter
Used to eliminate
external noise from
power supply line.
Note: The following
noise filters do not conform to the EMC
instructions. As for the noise filters
conforming to EMC instructions, refer
to 7.2.2.
Types: LF-205A
(for DR2-A3A, A5A, 01A,
02A, A3B, A5B, and 01B)
LF-210
(for DR2-04A and 02B)
LF-220
(for DR2-03B and 08A)
Magnetic contactor
Turns the main power ON
or OFF.
Use a surge suppressor
for the magnetic contactor.
Type: HI-15E5 (30 A)
Brake power supply
Used for Servomotor with brake.
Types:
(for 200 V input)
(for 100 V input)
Regenerative unit
(For types DR2-A3A,
A5A, 01A, 02A)
Type: JUSP-RG08
(Not applicable to types
DR2 A3B, A5B, 01B)
Exterior type regenerative
resistor
Applicable to DR2-04ACY8,
08ACY8, 02BCY8, 03BCY8)
26
LPSE-2H01
LPDE-1H01
This wiring is required
This wiring is required
only for a Servomotor
only for a Servomotor
with brake
with brake
Power supply:
Digital Operator
Single-phase
200 or 100 V
Allows the user
to set user
constants or
operation
references and
display operation
status or alarm
status.
Brake
control
relay
See the precautions
on wiring (on the
previous page).
+(Y3), -(Y4)
U
V
W
Connector for PG
Connector for PG
(on Servopack side)
(on Servopack side)
Connector kits for pulse generator (PG) and for
motor are not required if the following parts are
ordered:
S Cable with terminal connectors
S Cable with connector and amplifier terminal
Hand-held type
(JUSP-OP02A-1)
1-meter(3.3ft.) cable included
S-Series
DR2 Servopack
L1
L2
L
N
U
V
W

Hide quick links:

Advertisement

Table of Contents
loading