USING THE DIGITAL OPERATOR
4.1.5 Operation in User Constant Setting Mode cont.
4
TERMS
178
3) Using the Setting Mode for Memory Switches (Cn-01, Cn-02)
Turn the bits of the memory switches ON and OFF to select the functions required.
The example below shows how to turn ON Bit 4 of memory switch Cn-01.
1) Press
DSPL
to select the user constant
SET
setting mode.
2) Select the user constant number to set.
Press the
and
digit.
Press the
and
value.
DATA
3) Press
to display the current data for
ENTER
the memory switch selected at step 2.
4) Press the
and
bit number to set.
5) Press the
memory switch data ON or OFF for the bit
number.
6) Repeat steps 4 and 5 as often as required.
DATA
7) Press
to store the data.
ENTER
Turning Bits ON and OFF
Memory switches use bits, not numbers, to select
functions.
Sixteen bits are available (1 to 9 and A to E). Select
the required functions by turning the appropriate bit
ON (function ON) or OFF (function OFF).
keys to select the
keys to change the
keys to select the
and
keys to set the
Setting
Mode
The selected
digit flashes.
Memory
User Constant
Switch Data
Number
Bit Number to Set
Bit
Number
Press either key.
or
The stored data
flashes.
: = OFF
= ON
Bit
Number
to Set

Hide quick links: