• Use the following user constant to set the pulse dividing ratio.
PGRAT
Dividing Ratio
Cn-0A
Setting
Set the number of output pulses for PG output
signals (PAO,
PAO, PBO and
*
Pulses from motor encoder (PG) are divided
by the preset number of pulses before being
output.
The number of output pulses per revolution is
set in this user constant. Set this value accord-
ing to the reference unit of the machine or con-
troller to be used.
The setting range varies according to the en-
coder used.
Number of Encoder Pulses Per
Motor Type
Revolution
SGM-jjj31j
Incremental encoder: 2048 pulses
SGMP-jjj31j
per revolution
SGM-jjjW1j
Absolute encoder: 1024 pulses per
SGMP-jjjW1j
revolution
Unit: P/R
Setting Range:
16 to Number
of Encoder
Pulses
PBO).
*
Servomotor
encoder
Setting example:
3.8 Special Wiring
Factory
For Speed/Torque
Setting:
Control and
2048
Position Control
Output terminals:
PAO (1CN-33)
Servopack
*PAO (1CN-34)
PBO (1CN-35)
*PBO (1CN-36)
Phase A
Phase A
Fre-
quency
Phase B
divider
Phase B
Output
Preset value: 16
1 revolution
Setting Range
16 to 2048
16 to 1024