YASKAWA SGM-A3 User Manual page 446

Sigma series ac servomotors and driver sgm series sgmp series servomotors dr2 servopack
Table of Contents

Advertisement

2) Adjustment Procedure
a) Set the position loop gain at the host controller to a low value and increase the speed
loop gain (Cn-04) within the range that no abnormal noise or vibration occurs.
If adjustment of the position loop gain is not possible at the host controller, reduce the
speed reference gain (Cn-03).
b) Slightly reduce the speed loop gain from the value at step 1, and increase the position
loop gain at the host controller in the range that no overshooting or vibration occurs.
If adjustment of the position loop gain is not possible at the host controller, increase
the speed reference gain (Cn-03).
c) Determine the speed loop integration time constant (Cn-05), by observing the posi-
tioning setting time and vibrations in the mechanical system.
The positioning setting time may become excessive if the speed loop integration time
constant (Cn-05) is too large.
d) It is not necessary to change the torque reference filter time constant (Cn-17) unless
torsional resonance occurs in the machine shafts.
Torsional resonance may be indicated by a high vibration noise. Adjust the torque ref-
erence filter time constant (Cn-17) to reduce the vibration noise.
e) Finally, fine adjustment of the position gain, speed gain, and integration time constant
is required to determine the optimum point for step response.
B.2 Adjusting a Servopack for Speed Control