Figure 4.290Security > Port Access Control > Statistics - Advantech EKI-9516P-HV User Manual

Eki-9500 series
Table of Contents

Advertisement

Item
Maximum Users
Refresh
4.6.1.5
Statistics
Use the Port Access Control Statistics page to view information about the Extensible
Authentication Protocol over LAN (EAPOL) frames and EAP messages sent and
received by the local interfaces.
To access this page, click Security > Port Access Control > Statistics.
Figure 4.290 Security > Port Access Control > Statistics
The following table describes the items in the previous figure.
Item
Interface
PAE Capabilities
EAPOL Frames
Received
EAPOL Frames
Transmitted
Last EAPOL Frame
Version
Last EAPOL Frame
Source
Refresh
Details
Clear
4.6.1.6
Client Summary
The Port Access Control Client Summary page displays information about supplicant
devices that are connected to the local authenticator ports. If there are no active
802.1X sessions, the table is empty.
EKI-9500 Series User Manual
Description
The maximum number of clients supported on the port if the Control
Mode on the port is MAC-based 802.1X authentication.
Click Refresh to update the screen.
Description
The interface associated with the rest of the data in the row. When
viewing detailed information for an interface, this field identifies the
interface being viewed.
The Port Access Entity (PAE) role, which is one of the following:
Authenticator: The port enforces authentication and passes
authentication information from a remote supplicant (similar to a
client or host) to the authentication server. If the server success-
fully authenticates the supplicant, the port allows access.
Supplicant: The port must be granted permission by the authenti-
cation server before it can access the remote authenticator port.
The total number of valid EAPOL frames received on the interface.
The total number of EAPOL frames sent by the interface.
The protocol version number attached to the most recently received
EAPOL frame.
The source MAC address attached to the most recently received
EAPOL frame.
Click Refresh to update the screen.