Figure 4.227Switching > Lldp > Interface - Advantech EKI-9516P-HV User Manual

Eki-9500 series
Table of Contents

Advertisement

The following table describes the items in the previous figure.
Item
Transmit Interval
(Seconds)
Transmit Hold Multi-
plier (Seconds)
Re-Initialization
Delay (Seconds)
Notification Interval
(Seconds)
Submit
Refresh
Cancel
4.4.14.2
Interface
Use the LLDP Interface Summary page to specify LLDP parameters that are applied
to a specific interface.
To access this page, click Switching > LLDP > Interface.
The following table describes the items in the previous figure.
Item
Interface
Link Status
Transmit
Receive
Notify
Optional TLV(s)
Description
The number of seconds between transmissions of LLDP advertise-
ments.
The Transmit Interval multiplier value, where Transmit Hold Multiplier -
Transmit Interval = the time to live (TTL) value the device advertises to
neighbors.
The number of seconds to wait before attempting to reinitialize LLDP
on a port after the LLDP operating mode on the port changes.
The minimum number of seconds to wait between transmissions of
remote data change notifications to the SNMP trap receiver(s) config-
ured on the device.
Click Submit to save the values and update the screen.
Click Refresh to update the screen.
Click Cancel to restore default value.
Figure 4.227 Switching > LLDP > Interface
Description
The interface associated with the rest of the data in the row. Only inter-
faces that have at least one LLDP setting enabled appear in the table.
In the Add LLDP Interface window, use this field to select the interface
with the LLDP settings to configure. In the Edit LLDP Interface window,
this field identifies the interface that is being configured.
The link status of the interface, which is either Up or Down. An inter-
face that is down does not forward traffic.
The LLDP advertise (transmit) mode on the interface. If the transmit
mode is enabled, the interface sends LLDP Data Units (LLDPDUs) that
advertise the mandatory TLVs and any optional TLVs that are enabled.
The LLDP receive mode on the interface. If the receive mode is
enabled, the device can receive LLDPDUs from other devices.
The LLDP remote data change notification status on the interface. If
the notify mode is enabled, the interface sends SNMP notifications
when a link partner device is added or removed.
Indicates which optional LLDP TLV(s) are included in the LLDPDUs
that the interface transmits:
0: Port Description
1: System Name
2: System Description
3: System Capabilities
205
EKI-9500 Series User Manual

Advertisement

Table of Contents
loading

Table of Contents