Sign In
Upload
Manuals
Brands
Datalogic Manuals
Scanner
MAGELLAN 1000I
Datalogic MAGELLAN 1000I Manuals
Manuals and User Guides for Datalogic MAGELLAN 1000I. We have
2
Datalogic MAGELLAN 1000I manuals available for free PDF download: Product Reference Manual, Quick Reference Manual
Datalogic MAGELLAN 1000I Product Reference Manual (176 pages)
On-Counter Presentation Omnidirectional Bar Code Reader
Brand:
Datalogic
| Category:
Barcode Reader
| Size: 4 MB
Table of Contents
Table of Contents
3
About this Manual
7
Manual Conventions
7
Connecting the Scanner
8
Programming
9
Using the Programming Barcodes
9
Resetting the Standard Product Defaults
9
LED and Beeper Indicators
10
Error Codes
11
Double Read Timeout
13
Label Gone Timeout
15
Productivity Index Reporting (PIR)
15
Sleep Mode
16
LED and Beeper Indicators
18
Power on Alert
18
Good Read: When to Indicate
19
Good Read Beep Control
20
Good Read Beep Frequency
20
Good Read Beep Length
21
Good Read Beep Volume
22
Scanning Features
23
Targeted Scanning Mode
23
Target Mode Active Time
23
Target Mode Linger Time
24
Wake up Intensity
25
Interface Related Features
27
Interface Selection
29
Interface Features
33
Obey/Ignore Host Commands
33
Host Transmission Buffers
34
RS-232 Interface Features
35
Hardware Flow Control
37
Intercharacter Delay
38
Software Flow Control
39
Host Echo
40
Host Echo Quiet Interval
41
Signal Voltage: Normal/Ttl
42
Beep on ASCII BEL
43
RS-232 Invert
43
Beep on Not on File
44
ACK NAK Options
45
ACK Character
46
NAK Character
46
ACK NAK Timeout Value
47
Retry on ACK NAK Timeout
47
ACK NAK Retry Count
48
ACK NAK Error Handling
49
Transmission Failure Indication
50
USB-OEM Interface Features
50
USB-OEM Device Usage
50
Ibm
51
IBM Transmit Labels in Code 39 Format
51
Wand Emulation
52
Supported Symbologies
52
Wand Emulation Barcode Format
52
Bar/Space Polarity
53
Product Reference Guide
53
Wand Idle State
53
Signal Speed
54
Transmit Trailing Noise
54
Transmit Leading Noise
55
Symbology Conversion
55
Keyboard Wedge
56
USB Keyboard
56
Caps Lock State
58
Data Editing Overview
63
Please Keep in Mind
63
Global Prefix/Suffix
64
Aim ID
66
Label ID
67
Case Conversion
74
Character Conversion
75
Upc-A
77
Disable/Enable UPC-A
77
Check Digit Transmission
78
Expand UPC-A to EAN-13
78
Number System Transmission
79
UPC-A Minimum Reads
79
UPC-A In-Store Minimum Reads
80
Upc-E
81
Disable/Enable UPC-E
81
Check Digit Transmission
81
Number System Digit
82
Expand to UPC-E to UPC-A
82
Expand UPC-E to EAN13
83
Minimum Reads
83
Gtin
84
Expand UPC/EAN to GTIN
84
Disable/Enable EAN-13
85
Check Digit Transmission
85
EAN-13 Flag 1 Character
86
Isbn
86
Minimum Reads
87
Disable/Enable EAN-8
88
Check Digit Transmission
88
Minimum Reads
89
Enable EAN Two-Label
90
Add-Ons
91
GS1 Databar Omnidirectional / Stacked Omnidirectional
93
Disable/Enable GS1 Databar Omnidirectional
93
UCC/EAN 128 Emulation
93
Minimum Reads
94
GS1 Databar Expanded / Expanded Stacked
95
Disable/Enable GS1 Databar Expanded
95
GS1-128 Emulation
95
Length Control
96
GS1 Databar Expanded Length 1, Length 2 Programming Instructions
97
Minimum Reads
98
Coupon Read Control
99
GS1 Databar Limited
100
Disable/Enable GS1 Databar Limited
100
GS1-128 Emulation
100
Minimum Reads
101
Code 39
102
Disable/Enable Code 39
102
Check Character Calculation
102
Check Character Transmit
103
Start/Stop Characters
103
Code 39 Full ASCII
104
Length Control
105
Code 39 Length 1, Length 2 Programming Instructions
106
Quiet Zones
106
Code 39 Stitching
107
Minimum Reads
107
Pharmacode 39
108
Start/Stop Characters
108
Check Character Transmit
109
Code 128
110
Disable/Enable Code 128
110
Disable/Enable EAN 128
110
Transmit Function Characters
111
Length Control
112
Code 128 Conversion to Code 39
113
Code 128 Length 1, Length 2 Programming Instructions
113
Code 128 Stitching
114
Minimum Reads
114
Interleaved 2 of 5
115
Check Digit Calculation
115
Disable/Enable Interleaved 2 of 5
115
Check Digit Transmit
116
Length Control
117
Interleaved 2 of 5 Length 1, Length 2 Programming Instructions
118
Interleaved 2 of 5 Stitching
119
Minimum Reads
120
Codabar
121
Check Character Verification
121
Disable/Enable Codabar
121
Check Character Transmit
122
Length Control
123
Codabar Length 1, Length 2 Programming Instructions
124
Quiet Zones
124
Start/Stop Character Transmission
125
Start/Stop Character Type
125
Codabar Stitching
126
Start/Stop Character Match
126
Minimum Reads
127
Code 93
128
Disable/Enable Code 93
128
Length Control
129
Code 93 Length 1, Length 2 Programming Instructions
130
Code 93 Stitching
131
Minimum Reads
131
Msi/Plessey
132
Check Digit Verification
132
Disable/Enable Msi/Plessey
132
Check Digit Transmit
133
Number of Check Characters
133
Length Control
134
Msi/Plessey Length 1, Length 2 Programming Instructions
135
Msi/Plessey Stitching
136
Minimum Reads
137
Standard 2 of 5
138
Check Digit Verification
138
Disable/Enable Standard 2 of 5
138
Check Digit Transmit
139
Length Control
140
Standard 2 of 5 Length 1, Length 2 Programming Instructions
141
Standard 2 of 5 Stitching
142
Product Reference Guide I-III
143
Minimum Reads
143
2D Symbologies
146
Pdf 417
146
Disable/Enable PDF 417
146
Length Control
147
PDF 417 Length 1, Length 2 Programming Instructions
148
Minimum Reads
149
Datamatrix
150
Disable/Enable Datamatrix
150
Length Control
151
Datamatrix Length 1, Length 2 Programming Instructions
152
Minimum Reads
153
Image Capture
154
How to Capture an Image
154
Captured Image Format
154
Product Specifications
155
Optical and Read Performance Parameters
155
Scanner Dimensions
155
Physical Properties
156
Electrical Parameters
156
Environmental Parameters
156
Other Parameters
156
Standard Cable Pinouts (Primary Interface Cables
157
IBM Port 5B/9B/17
157
Usb-Oem
158
USB, USB Keyboard & USB COM
158
Wand Emulation
158
Keyboard Wedge
158
Default Settings
161
Defaults by Symbology
161
Interface Default Exceptions
162
IBM Interfaces
162
RS-232 Wincor/Nixdorf
163
Wand Emulation
164
Keyboards
164
Keyboard Model Cross Reference
165
Accepting RS-232 Commands
171
Sample Symbols
173
Ascii Chart
175
Advertisement
Datalogic MAGELLAN 1000I Quick Reference Manual (45 pages)
Omni-Directional Imaging Scanner
Brand:
Datalogic
| Category:
Scanner
| Size: 1 MB
Table of Contents
Quick Reference
9
Installation
9
Optional Stand
10
Power Supply
10
How to Scan
10
Troubleshooting
11
Targeted Scanning Mode
11
Compliance Statement
12
Guida Rapida
13
Installazione
13
Come Utilizzare lo Scanner
14
Risoluzione Dei Problemi
15
Dichiarazione DI Conformità
16
Guía de Referencia Rápida
17
Instalación
17
Suministro Eléctrico
18
Instrucciones para Escanear
18
Solución de Problemas
19
Referência Rápida
21
Como Fazer Leitura
22
Declaração de Conformidade
24
Guide de Référence Rapide
25
Installation
25
Alimentation Électrique
26
Comment Scanner
26
Diagnostic de Pannes
27
Déclaration de Conformité
28
Led Class
28
Fehlerbehebung
31
Declaration of Conformity
43
Advertisement
Related Products
Datalogic Magellan 1500i
Datalogic MAGELLAN 3200VSI
DATALOGIC MAGELLAN 8300
DATALOGIC MAGELLAN 8400
Datalogic Magellan 3300HSi
Datalogic Magellan 9800i
Datalogic Magellan 3450VSi
Datalogic Magellan 3500HSi
Datalogic MAGELLAN 3410VSi
Datalogic MAGELLAN 3510HSi
Datalogic Categories
Barcode Reader
Scanner
Accessories
PDA
Handhelds
More Datalogic Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL