State Number for Complex Trigger Sequences

To follow the path of complex trigger sequences, you can display state number.
To see state number, in Packet View right‐click a link layer packet, show field, and select
state number.

Setting Trigger Conditions

To set the If and Else If trigger condition:
1. Click the Add Pattern button
Figure 2.78: SAS: Choosing a Trigger Condition
2. Define each selected pattern in the same way as in Easy Mode, as described starting
Note:
You can set a timer for any If or Else If condition.
3. Enter a value for the number of occurrences before trigger in the Cont field, up to a
4. Choose a capture option: Everything, Nothing, or Pattern.
5. If you choose Pattern, you can select patterns for inclusion or exclusion. Clicking the
Figure 2.79: SAS: Choosing a Pattern
104
 
from the drop‐down list.
on page 59. To use a timer, define it first.
maximum of 65535 occurrences.
Pattern option enables a pattern definition dialog.
for a Pattern field and choose a trigger condition
S ierra M6‐2 SAS/SATA Protocol Analyzer User Manual
 