Insert Primitive
Check Insert Primitive, click the Type button to open the Primitive Type dialog, select the
primitive type, and click OK.
Destroy Field of Frame
Make sure to click the More button and then check the field to destroy.
Insert Frame
Check Insert Frame, click the down arrow on the Type combo box, and choose the frame
type. Make sure that you have clicked More.
Incoming Frame Settings
Before selecting Incoming Frame Settings, select the Types Of Frames and the
Frame Number on which to inject an error. Then check Incoming Frame in the Generate
Error On area and then the enabled Settings button to display the Incoming Frame
Settings dialog.
Figure 2.179: Incoming Frame Setting Dialog
Handshake Error
Check Handshake Errors to enable selection of error on handshake. Check NAK, CRC, or
any other Primitive to send as an incoming frame response. Check No Handshake to send
no response.
Defer Handshake Errors
Check Defer Handshake and enter a value for the time to defer the handshake.