LeCroy Sierra M6-2 User Manual page 133

Sas/sata protocol analyzer
Table of Contents

Advertisement

Exercise and Capture
Frame Length Error
Check Frame Length Error and choose the type of error to introduce.
Code violation and Disparity error
Check these and specify DWORD offset and number of error DWORDs.
Additionally check:
No WTRM
Code Violation on SATA primitive
Disparity error on SATA primitive
Ignore XRDY/RRDY sequence
Delay in HOLD response (in sending HOLDA)
SOF, EOF and CRC errors
Check these and specify Double or Omit by checking the corresponding option button.
Insert Primitive
Check Insert Primitive and then click the Type button to open the Primitive Type dialog
and select the primitive type.
Figure 2.129: Primitive Type Dialog
Click the down arrow on the Primitive combo box, choose a primitive, then click OK.
Fill reserved fields with
Enter a value for which reserved fields to change, if other than 0.
Field of Frame
Select Destroy, scroll through the available choices in the Field of Frame list box, and
choose a field to destroy. Alternatively, select Specify Value to fill the chosen field with a
pre‐defined value.
       
S ierra M6‐2 SAS/SATA Protocol Analyzer User Manual
LeCroy Corporation
131

Advertisement

Table of Contents
loading

Table of Contents