LeCroy LogicStudio Getting Started Manual

LeCroy LogicStudio Getting Started Manual

Logic analyzer

Advertisement

Quick Links

 
 
 
 
 
LogicStudio 
 
Getting Started Manual 
April, 2010

Advertisement

Table of Contents
loading

Summary of Contents for LeCroy LogicStudio

  • Page 1           LogicStudio    Getting Started Manual  April, 2010...
  • Page 2   LeCroy Corporation    700 Chestnut Ridge Road   Chestnut Ridge, NY, 10977‐6499   Tel: (845) 578‐6020, Fax: (845) 578 5985 Warranty NOTE: THE WARRANTY BELOW REPLACES ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED  WARRANTY OF MERCHANTABILITY, FITNESS, OR ADEQUACY FOR ANY PARTICULAR PURPOSE OR USE. LECROY SHALL NOT BE LIABLE FOR ANY  SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHETHER IN CONTRACT OR OTHERWISE. THE CUSTOMER IS RESPONSIBLE FOR THE  TRANSPORTATION AND INSURANCE CHARGES FOR THE RETURN OF PRODUCTS TO THE SERVICE FACILITY. LECROY WILL RETURN ALL PRODUCTS  UNDER WARRANTY WITH TRANSPORT PREPAID.  The instrument is warranted for normal use and operation, within specifications, for a period of one year from shipment. LeCroy will either  repair or, at our option, replace any product returned to one of our authorized service centers within this period. However, in order to do this  we must first examine the product and find that it is defective due to workmanship or materials and not due to misuse, neglect, accident, or  abnormal conditions or operation.   LeCroy shall not be responsible for any defect, damage, or failure caused by any of the following: a) attempted repairs or installations by  personnel other than LeCroy representatives or b) improper connection to incompatible equipment, or c) for any damage or malfunction  caused by the use of non‐LeCroy supplies. Furthermore, LeCroy shall not be obligated to service a product that has been modified or integrated  where the modification or integration increases the task duration or difficulty of servicing the instrument. Spare and replacement parts, and  repairs, all have a 90‐day warranty.  The instrument firmware has been thoroughly tested and is presumed to be functional. Nevertheless, it is supplied without warranty of any  kind covering detailed performance. Products not made by LeCroy are covered solely by the warranty of the original equipment manufacturer.  Internet: www.lecroy.com  © 2010 LeCroy Corporation    by  . All rights reserved. LeCroy, ActiveDSO, JitterTrack, WavePro, WaveMaster, WaveSurfer, WaveLink, WaveExpert, Waverunner, and WaveAce are registered  trademarks of LeCroy Corporation. Other product or brand names are trademarks or requested trademarks of their respective holders.    Information in this publication supersedes all earlier versions. Specifications are subject to change without notice. This electronic product is subject to disposal and recycling  Manufactured under an ISO 9000  regulations that vary by country and region. Many countries    Registered Quality Management System.
  • Page 3: Table Of Contents

    Signals List  ................................ 23  Instrument ............................... 24  Trigger ................................ 24  The Menu Bar .............................. 26  Save/Load Setup, Acquisition, or Screenshot  .................... 26  Save/Load Setup .............................. 26  Default Setup .............................. 26  Save/Load Acquisition  ............................ 26  Save Screenshot  ............................... 26  Devices .............................. 26  Device Connections  ............................ 26  Simulate Devices .............................. 26  Setup ................................. 26  The Mixed Signal Setup Dialog  ......................... 27  Help ................................ 27  Tell LeCroy  ................................ 27  Reference  ............................... 28  China RoHS Compliance .......................... 28  China RoHS Compliance (English Version)  .................... 29  EC Declaration of Conformity ........................ 30    iii  918291 RevA...
  • Page 4: Introduction

    Getting Started Manual  Introduction This document provides an overview of the LogicStudio application features and describes how to perform  various operations. Software interface updates may result in a slight difference between screenshots seen in this  manual (running on Windows Vista®) and the interfaces you’ll find from the software and operating system  versions you’re running. Different versions of the application and/or running the application under different  operating systems may result in slight interface appearance differences. Regardless, the differences do not  prevent you from easily following the explanations.      918291 RevA ...
  • Page 5: Safety Requirements

    LogicStudio  Safety Requirements This symbol may appear on the product:    This refers you to additional information contained in the operator’s manual. The corresponding information in  this manual is similarly denoted.  Operating Environment Before using your LeCroy LogicStudio 16, ensure its operating environment will be maintained within these parameters: • Indoor use; • Altitude up to 3000 m; • Temperature 5 C to 50 •...
  • Page 6: Software And Driver Installation

    Getting Started Manual  Software and Driver Installation The most recent LogicStudio installer is available as a .zip file from the LeCroy website at www.lecroy.com.   • Choose to Save the .zip file to a location on your local computer.  • When the .zip file is completely downloaded to your machine, double‐click the file to open its contents. Two  files and two folders should be shown.  • Double‐click the file named Setup.exe to launch the installer.  The installer guides you through proper setup of both the LogicStudio software and necessary drivers for your  computer as explained in the following topics.  Software Installation The LogicStudio Setup Wizard is then shown. Click Next to proceed with the installation.    Note: Included in this installation process is Microsoft .NET 3.5 SP1 (Service Pack 1). This version (or greater) is  required to run the LogicStudio software properly.    918291 RevA ...
  • Page 7 LogicStudio  Agree to the terms of the End User License Agreement by selecting I Agree, and then click the Next button to  continue.    You can leave the default Installation Folder path, or specify a new location. Also, determine whether or not to  install the software for yourself or anyone who uses the computer. After making the desired settings, click Next  to proceed.      7   918291 RevA...
  • Page 8: Driver Installation

    Getting Started Manual  The Confirm Installation screen is shown. Click Next to start your installation.    Driver Installation The Wizard then notifies you that the LogicStudio installer contains signed and unsigned drivers. Windows®  prompts you to this affect by showing driver confirmation dialogs.    Note: Keep in mind that installation interface screens differ slightly between Windows® operating systems.  Regardless of appearance, choose the option to Install or Continue Anyway when prompted about LogicStudio  drivers.    918291 RevA ...
  • Page 9 LogicStudio  Click the Continue button to proceed.    Note: The previous screen differs slightly between Windows® operating systems. Again, regardless of  appearance, choose the option to Continue when prompted.  The progress of the LogicStudio installation is then shown.      9   918291 RevA...
  • Page 10 Getting Started Manual  The Wizard then lets you know that you can attach your device to the computer once the installation has  finished.    Note: Depending on your operating system, Windows® shows additional driver interfaces when LogicStudio is  actually plugged into your computer. Always choose the Install the software automatically option and click  the Next button to complete the driver installation.      918291 RevA ...
  • Page 11 LogicStudio  The Installation Complete screen is shown. Click the Close button to complete the installation.    Now, with correct application software and drivers installed, your LogicStudio is ready for use.    11   918291 RevA...
  • Page 12: The Waveform Display Area

    Getting Started Manual  The Waveform Display Area The Waveform Display Area takes up the largest portion of the application display space because it’s where  configured signal waveforms are shown.    Navigation The user can navigate the Waveform Display Area and make various view adjustments using the following  controls:  • Panning the Timeframe ‐ Left‐click and drag left/right and the waveform display area moves in the  direction you’ve chosen.  • Zoom a Specific Region – Hold Control, left‐click, and drag left/right. When the mouse button is  released, your zoom is shown in the waveform display area.  • Scale the Timeframe (Click‐and‐Drag) ‐ Right‐click and drag left/right to scale the timeframe and view  (zoom in/out) around the center point of the view.  OR  • Scale the Timeframe (Mousewheel) – You can alternatively scale the timeframe using the mousewheel  by putting your mouse pointer anywhere inside the waveform display area and mousewheeling  up/down (instead of right‐clicking and dragging left/right). Mousewheeling advances in 10% increments.  Note: Along with these navigation tools, you can also double‐click any area on the waveform display area to  automatically center the view at the point of your selection.    918291 RevA ...
  • Page 13: Scale And Grid

    LogicStudio  Scale and Grid A timescale is displayed along the top edge of the waveform display area at all times. The scale steps and labels  dynamically adjust based on the current timeframe shown. Labeled tick marks have dashed grid lines extending  the full height of the display providing waveform reference.    Interacting with Cursors Cursors are easily applied to the waveform display area (see The Cursors Tool topic for more information).  Tools Controls for LogicStudio’s built in Tools are located in the space above the Waveform Display Area. The built in  tools include controls for Cursors, RearView, and Magnifier, respectively.    Toggle the Cursors and Magnifier tools (RearView is always on) on or off by clicking the main portion of the  control (containing the icon). Click the right side of the control to access detailed controls related to each tool.  The Cursors Tool This topic demonstrates the use of the Cursors tool.    When the Cursor tool is enabled, you are currently armed with the selected cursor pair on the waveform  display. When expanded, the tool’s detailed control provides storage for up to 4 cursor pairs. When cursors are  placed on the display, they are highlighted when the pair is selected from the numbered cursor pair. Remove a  pair by clicking the Remove Cursor button on the right side of the numbered cursor pair.  Cursors are controlled and interacted with in the following ways:  • Selecting a cursor pair button activates the pair.  • Pressing the Remove Cursor button for the pair deletes them from the display.    • Double‐clicking a cursor pair button automatically zooms and centers the pair on the Waveform Display  Area.  Mark cursor pairs on signals in the waveform display using the following steps:  1. Select a cursor pair (1‐4) from the tools detailed control.  2. Left ‐click the display to place cursor A (of the pair) at the first location. ...
  • Page 14 Getting Started Manual  PLEASE NOTE THE FOLLOWING:   • The time difference (and frequency between A and B) is shown on both the Waveform Display Area  and on the Cursor’s Tool.  • When a single cursor (of the pair) is placed, the time and frequency is shown in real‐time based on  mouse position until the second half of the pair is placed (by right‐clicking on the waveform).  • Placing the mouse over the active cursor pair shows the horizontal click‐and‐drag mouse icon.  When this icon appears, you can horizontally click‐and‐drag a cursor to a new location. The display  values are updated accordingly.    • Clicking a created cursor in the waveform display automatically selects the cursor pair and enables  the cursor tool.  • When placing or moving a cursor over any digital signal, the software looks for any nearby edges on  the signal and snaps the cursor to that edge. This allows for easier, precise measurements between  edges. When the cursor is successfully snapped to an edge, the cursor’s color changes to match the  signal. Snapping does not occur when the mouse pointer is positioned above or below the  waveform.  • Cursors that cross Analog or Digital Wave signals also display the value of the signal where it meets  the cursor as follows:      918291 RevA ...
  • Page 15: Rearview

    LogicStudio  The following screenshot shows a cursor pair placed on the waveforms display.    RearView The RearView tool allows you to store and navigate through a history of data acquisitions retrieved from the  device(s). The expanded RearView tool’s detailed control looks like the following:    RearView keeps a history of the last N acquisitions. View your stored acquisitions by setting your trigger to Stop  and using the slider on the detailed control to flip through the history. The currently selected acquisition is  shown in the waveform display area.  You can change the number of stored acquisitions by providing a new number in the text box at the right end of  the tool’s detailed control.  The blue bar on the slider control displays how much of the RearView history is being used and available for  review. This bar fills up as you make new acquisitions until reaching your specified depth; at which point the  oldest acquisition is discarded when a new one is received.  Note: The RearView tool is always enabled. The default acquisition depth is set to 20 records.  The specific acquisition being viewed is always shown above the slider control – for example in the previous  screenshot the tool is showing acquisition 11 of 20 possible acquisitions. When you acquire a new acquisition  the RearView tool automatically adjusts to show the most recent acquisition.  TIPS:   • While using the RearView tool, you can modify your signal setup at any time and display additional  signals/data in different ways than how it may have been set at the time of the actual signal  acquisition.  • You can create a persistence display to compare acquisitions AFTER all the necessary acquisitions have  been obtained. Do this by enabling persistence mode, and then navigating through various  acquisitions available in the RearView tool. You can even generate a persistence display for a  timeframe or zoom level – even if the signal data was not yet visible at the time of acquisition.    15   918291 RevA...
  • Page 16: Magnifier

    Getting Started Manual  Magnifier The Magnifier tool allows you to quickly zoom‐in on a selected time‐period of your acquisition without having to  adjust your main display or lose your frame of reference.    Enable the magnifier tool at any time by clicking the main portion of the control. Now, move your mouse  anywhere over the waveform display and an additional, time‐magnified display is drawn inside a boxed,  magnified area. Use the slider control or mousewheel to adjust the magnification factor inside the time‐ magnified display. The slider bar updates along with your mousewheel adjustments.  With the magnifier tool enabled, you can still adjust the timeframe of the main waveform display by holding the  Control key down while scrolling the mousewheel, or dragging with the left and right mouse buttons as normal.  Tip: This tool conveniently provides a quick, magnified view of closely aligned edges or visibility of decode and  bus value text.    WorldView The WorldView is an extremely powerful control just above the waveform display on the dashboard. Not only  does it provide important high‐level waveform information, but it also allows for display configuration and even  pre/post‐store settings. The control looks like the following:    The WorldView is primarily a high‐level presentation of the current relationship between your displayed  acquisition(s) and your current view in the main waveforms display.    918291 RevA ...
  • Page 17: Run Modes

    LogicStudio  The display automatically updates to reflect the current conditions whenever display adjustments or a new  acquisition is obtained.  • The blue horizontal bar represents the digital samples acquired. The labels on each end of the bar  show the time extent of that data relative to the trigger point.  • The red horizontal bar represents analog samples (if present) acquired from an attached  oscilloscope and the labels on each end of the bar show the time extent of that data relative to the  trigger point.  The trigger point itself is denoted by the solid vertical green bar (A).   The current pre/post‐store setting for the digital device is denoted by the dashed green rectangle (B). These two  indicators align when a new acquisition is obtained; however, the pre/post‐store control can be adjusted by the  user to change the setting for subsequent acquisitions. The pre‐store amount (as a percentage of the total  digital acquisition) is always displayed next to this rectangle.  The yellow translucent viewbox represents your current view in the waveforms display. This shaded region also  provides information for relative zoom level and position within the acquired data.  WorldView control uses include the following:  • Left‐click and drag the yellow, translucent viewbox to pan the waveform display (to the left or right)  through the acquired data.  • Increase/decrease the current timeframe by left‐clicking and dragging the left or right edges of the  viewbox. This adjusts or stretches the left or right‐most visible time point on the display while leaving  the other side pinned.  • Replace the existing viewbox with a new one by left‐clicking outside the existing one and dragging to  the desired timeframe size.  • Center your existing viewbox by right‐clicking outside the existing one. This centers the viewbox around  the point in time.  • Change the pre/post‐store setting for the digital device by left‐clicking and dragging the pre/post‐store  control (B). The ratio displayed as a percentage next to the indicator.  • Auto‐adjust the view to exactly fit the complete timeframe of any digital and analog data currently  displayed by clicking the button directly to the left of the WorldView display.  Run Modes Four run mode buttons are available on the upper‐right of the dashboard as follows: ...
  • Page 18: Persistence

    Getting Started Manual  Persistence Directly above the run mode buttons on the dashboard are the Persistence controls. Click the Persist button to  toggle the function on/off. When persistence is on, subsequent acquisitions are received and shown on the  waveform display. Use the Clear button to remove the waveforms from the display and restart your  acquisitions.  Note: The Clear button also clears your RearView history.    Status Display At times an animated status display appears in the upper‐right corner of the dashboard (above the Persistence  and Clear controls). This display provides messages when certain device actions are taking a longer period of  time.  For example, the Status Display indicates when the software is waiting for a trigger to occur, accumulating a  large pre/post‐store, or downloading data from an oscilloscope.    Signals Control Panel The signals control panel is located on the main window to the left of the waveform display area as follows.  Controls on this panel allow for quick and easy signal display modifications.    Note: Signals contain icons indicating the waveform type they are configured to display.    918291 RevA ...
  • Page 19: Arranging Your Signals

    LogicStudio  Arranging Your Signals The display of signals can be modified directly through this control as follows:  • You can rearrange the order of the signals shown in the waveform display area. Rolling the mouse over  the grip area on the left of a given signal shows the vertical click‐and‐drag mouse icon. When this icon  appears, you can vertically click‐and‐drag the signal to a new location.    • You can resize the height of a given signal in the waveform display area by clicking‐and‐dragging the  bottom edge of a signal to increase/decrease its height.  • Add a new signal to the list by pressing the Add New Signal button. With a signals selected in the  waveform display area, click the Delete Selected Signal button to remove the signal and its  configuration. Delete signals one at a time.  The Context Menu Right‐click on the signal control side of a desired signal to show its corresponding context menu complete with  the following options:  • Add – Inserts a new signal after the one currently selected.  • Remove – Deletes the currently selected signal.  • Show/Hide – Allows you to remove signals from view without deleting the configuration.      19   918291 RevA...
  • Page 20: Modifying A Signal

    Getting Started Manual  • Stacked/Freeform Modes –The signal control panel automatically displays signals in Stacked mode ‐  meaning they are shown as individual rows listed in the waveform display area. However, when you  change the signal control panel setting to Freeform mode, you can use the grip area’s (on the left of a  given signal) vertical click‐and‐drag mouse icon to drag signals and superimpose them over other  signals in the waveform display area.  Note: When in Stacked mode, the grip area’s vertical click‐and‐drag mouse icon rearranges the order of  your signals (see Arranging Your Signals for more information) instead of superimposing the signals.    Channels 1 and 2 in Stacked Mode.    Channel 2 superimposed over Channel 1 using Freeform Mode.  Modifying a Signal Click a signal’s colored name box and corresponding details for the signal are shown on a dialog at the bottom of  the waveform display area. This dialog shows contents based on the selected signal’s type. It’s also the same  dialog used for individual rows on the Signals List setup screen.  The following screenshot shows a SPI decode signal dialog.    Complex Signals   Digital Bus, Digital Wave, and IS2/SPI/UART Decode type signals are all complex signals that can be comprised of  more than one source channel. Signals of these types have an expand/collapse button on their right side  allowing you to show/hide the individual source channels as Digital Line type signals.    918291 RevA ...
  • Page 21: The Data Table

    LogicStudio  These sub‐signals cannot be directly modified and are automatically named based on how they apply to the  complex signal. An example of an expanded SPI Decode is shown in the following screenshot.    The Data Table   Clicking the Data Table button on the right edge of a given signal (left of the waveform display area) shows a  pop‐up. The pop‐up contains a tabular list of all transition data associated with the signal as follows:    From this pop‐up, you can scroll through the data, use the Radix drop‐down field to change the data values  (provided the chosen signal supports your selection). The data can also be Exported to a CSV file.  Clicking or using the up/down arrow keys to select a row on the table centers the waveform display timeframe  on the selected sample and highlights the transition with a vertical bar glowing in the color of the given signal.  Use this feature to quickly jump the display to samples of interest on the Data Table.  Note: You can leave this pop‐up open for one or more signals while you capture new acquisitions. The table data  updates to show current information as acquisitions are completed.    21   918291 RevA...
  • Page 22: The Dashboard

    Getting Started Manual  The Dashboard The Dashboard is comprised of all control and information GUI elements seen when you first start the  application. You can perform many powerful operations and quickly access most of the functions from the  Dashboard.  Device Connections Two Device Connection buttons are shown on the upper‐left corner of the screen, just below the menu bars.  These buttons handle digital pod and oscilloscope device connections, respectively. Clicking either button  attempts to connect to the device or disconnect from the device (depending on the current state). These  buttons have a blue glow when the status is connected.    A red X over the button indicates the device is not currently present or has been explicitly disconnected by the  user.    You cannot make new acquisitions without a connection to a digital pod. However, you do not need to have an  oscilloscope connected to create acquisitions.  PLEASE NOTE THE FOLLOWING:   • Manually disabling or disconnecting the oscilloscope can speed up the rate of acquisitions if you  temporarily don’t need the analog data.  • LeCroy’s WaveJet series oscilloscope is the instrument used with LogicStudio.  Pin Activity The Pin Activity display is located at the top of the dashboard. It shows the activity status of all digital device  channels in real‐time (regardless of application or device state).    Setup Three Setup buttons are directly to the right of the device connection buttons. The Setup buttons allow for  configuring the application and digital device.      918291 RevA ...
  • Page 23: Signals List

    LogicStudio  Signals List Clicking the Signals button shows a screen containing a list of all signals to be rendered on the waveform display.  The Signal listing looks like the following:    The Signals list allows you to conveniently configure all the signals at the same time. Each row represents a  single signal. Inside a single row, you can modify the signal Type, Name, Color, and Source Channel(s), along  with additional options depending on the signal Type selected.  Supported signal Types include Digital Line, Digital Bus, Digital Wave, Analog Channel, and I2C/SPI/UART  Decodes.  Buttons at the top of the Signals list window allow you to add, delete, and reorder the list.    Note: Making any modifications to the Signals List or the Signal Setup in any way (even adding new signals)  immediately affects currently displayed acquisition data on the Waveform Display Area without requiring a  refresh from the device(s).    23   918291 RevA...
  • Page 24: Instrument

    Getting Started Manual  Instrument The Instrument setup button shows a configuration screen where you can configure how the digital instrument  samples data ‐ including the half/full channel mode selection and setting threshold levels. Changes made on the  Instrument setup screen take effect on the next acquisition.    Note: If you select a different channel mode, the information shown on the left of this setup display is updated  to match acquisition details for your choice.  Trigger The Trigger setup button opens a pop‐up used for configuring trigger conditions for the digital device. The  trigger pop‐up has four tabs for different trigger categories.  Note: It’s important to note that the trigger logic always runs at a rate of 500 MHz under all modes, regardless  of the selected Sample Rate. This allows you to continue triggering on fast events even when lowering the  Sample Rate to obtain a longer timeframe of data. However, this may result in trigger events that cannot be  seen in the slower sampled acquisition data when presented on the waveform display area.    IMPLE  OGIC  Use this tab to setup simple, logic‐based triggers. Modes include Edge, Level, Pattern, and Immediate triggers.    DVANCED  OGIC  Use this tab to set up more complex logic‐based triggers. You can set the trigger mode from Edge(s), Width,  Level(s), Qualified Level(s), Pattern, and Qualified Pattern choices. A different trigger mode can also be selected  for each of two trigger blocks (A and B) and then they can be combined in different logical ways including: A  only, B only, A and B, A or B, A then B, and B then A.    918291 RevA ...
  • Page 25 LogicStudio  The yellow arrows update to display the logical flow based on your choice. An example of the Advanced tab is  shown here.       ERIAL  ROTOCOL  Use this tab to define triggers on serial decode signals you may have defined for I2C, SPI, or UART protocols. An  example of an I C trigger is shown here.      XTERNAL  Use this tab to set the logic pod to trigger on an external input signal. A threshold voltage for the signal can be  specified.  Sample Rate The Sample Rate spinner control is located at the top of the dashboard just to the right of the Setup buttons. It  shows the selected rate of sampling for the digital pod. Use the up/down arrow buttons at the right of the  control to cycle through the higher/lower sample rates available on the device. Changes made on the Sample  Rate take effect on subsequent acquisitions.      25   918291 RevA...
  • Page 26: The Menu Bar

    Getting Started Manual  The Menu Bar The Menu Bar is a series of pull down listings along the top of the application screen. These pull down listings  provide access to some additional features and alternative ways use some aforementioned functions and  controls.  Save/Load Setup, Acquisition, or Screenshot Save/Load functions are accessed under File on the menu bar.  Save/Load Setup Located under File → Save/Load Setup on the menu bar, this function lets you save your current configuration  to a file or load a previously saved file back into LogicStudio. This includes all configurations of signals, device  settings, triggering, and view state.  Default Setup Located under File → Default Setup on the menu bar, this function resets the application setup to the default  configuration. The default setup contains 16 simple digital line signals D0 – D15.  Save/Load Acquisition Located under File → Save/Load Acquisition on the menu bar, this function allows you to save the complete set  of samples (digital and/or analog) included in your currently displayed acquisition. When using the RearView  tool, the currently selected acquisition is saved. The resulting acquisition file can then be re‐opened in  LogicStudio for further examination, or sent to another LogicStudio user (along with your Setup configuration)  for additional analysis. Data loaded into LogicStudio can be manipulated and displayed exactly the same as when  it’s acquired live.  Note: All raw samples are saved. This means you can reconfigure your signals after reloading an acquisition file  to view different channel in new ways.  Save Screenshot Located under File → Save Screenshot on the menu bar, this function provides an easy way for the user to  capture a screenshot of the application in its current state and save it to a specified location. Your screenshot  can be saved into most standard image formats.  Devices Devices functions are accessed under Devices on the menu bar.  Device Connections The LogicStudio 16 and oscilloscope options behave exactly like the Device Connections buttons on the ...
  • Page 27: The Mixed Signal Setup Dialog

    LogicStudio  The Mixed Signal Setup Dialog Located under Setup → Mixed Signal on the menu bar, this function shows the Mixed Signal Setup Dialog where  you can specify (in nanoseconds) an analog trigger alignment correction value. This setting can be used to fine‐ tune analog data acquired from the oscilloscope to the data from the digital pod (for example to compensate if a  different length of cross‐trigger cable is used). Positive values shift the analog trigger point later in time and  make the analog data move earlier in time relative to the digital data on the Waveform Display Area. Negative  value behaves inversely.    Help Help information is accessed under Help on the menu bar.  Access the User Manual to conveniently retrieve this same documentation or click About LogicStudio for the  software version and LeCroy contact information.     Tell LeCroy Under Help on the menu bar, the Tell LeCroy option is always available for providing your feedback. It creates  and sends an email to LogicStudio support at LeCroy. You can even automatically attach your current setup and  data with your feedback.    27   918291 RevA...
  • Page 28: Reference

    Getting Started Manual  Reference China RoHS Compliance     918291 RevA ...
  • Page 29: China Rohs Compliance (English Version)

    LogicStudio  China RoHS Compliance (English Version) PLEASE NOTE THE FOLLOWING:   O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is  • below the limit requirement specified in SJ/T11363‐2006.  X: Indicates that this toxic or hazardous substance contained in at least one of the homogenous materials used for  • this part is above the limit requirement specified in SJ/T11363‐2006.  EFUP (Environmental Friendly Use Period) Use Conditions: Refer to the environmental conditions stated in the  • specifications section of the Getting Started Manual.    29   918291 RevA...
  • Page 30: Ec Declaration Of Conformity

    Getting Started Manual  EC Declaration of Conformity   according to EN ISO/IEC 17050‐1:2004 & 17050‐2:2004      Manufacturer's Name: LeCroy Corporation  Manufacturer's Address: 700 Chestnut Ridge Road  Chestnut Ridge, NY, 10977‐6499  USA    Herewith declare that    Product/Model: LogicStudio 16    including all their options are in conformity with the provisions of the following EC directive(s), including the  latest amendments, and with national legislation implementing these directives:    2006/95/EC Low Voltage Directive  2004/108/EC EMC Directive    and that conformity with Council Directive 2006/95/EC is based on  EN/IEC 61010‐1:2001 ‐ Safety requirements for electrical equipment for measurement control and laboratory  use    and that conformity with Council Directive 2004/108/EC is based on  EN/IEC 61326‐1:2006 ‐ EMC requirements for electrical equipment for measurement control and laboratory use        By: David C. Graef  Vice President and Chief Technology Officer  Place: LeCroy Corporation  700 Chestnut Ridge Road  Chestnut Ridge, NY, 10977‐6499  USA  Date: 4/20/2010 ...

Table of Contents