Advanced Mode (User‐Defined)
6. Choose pattern(s) and click the +>> button to add them for capture or exclusion. You
7. For an output trigger, click the down arrow in the Ext. Out field and choose an
8. To go to another state, click the down arrow in the Go To field and select a state. If

Multi-Link Triggering

You can set different triggering for each link. To set different trigger conditions for a link,
check the Multi Sequencer check box and select the link for setup from the Port drop‐
down list.
Figure 2.80: Multi-Link Triggering Setup

Set Timers

You can set and use up to three timers for triggering. You can set each timer for each state
or continue from a timer set in the previous state. The timer defined for a particular state
starts when entering that state. To set timers, click the ellipses in the Timer field in each
state and define each of the timers in the Set Timers dialog.
Figure 2.81: Set Timers Dialog
       
S ierra M6‐2 SAS/SATA Protocol Analyzer User Manual
define each pattern the same way as in Easy mode
page
59.).
output trigger level. Note: Do not use the LOW setting in Advanced Mode.
no other state has been defined, choose New State to add a state.
LeCroy Corporation
(See "Defining Patterns" on
105