LeCroy Sierra M6-2 User Manual page 174

Sas/sata protocol analyzer
Table of Contents

Advertisement

LeCroy Corporation
If you enter 3 for Repeat Error, target emulator injects error on the 2nd, 3rd, 4th, 6th, 7th,
8th, 10th, 11th, and 12th commands. 
If you set Repeat Error to 0, it means infinity, and the system injects error on the 2nd, 3rd,
4th, 6th, 7th, 8th, 10th, 11th, 12th, 14th, 15th, 16th, 18th, 19th, 20th, 22th, 23th, 24th,
and so on commands. 
Note:
Repeat error resets the target emulator received command counter.
In the API, use the following functions:
3. Click the Command fail with check condition check box, click the down arrow on
4. Set up Outgoing and Incoming frame errors.
Note:
Once you check the Generate Error On: check box for a command, a red status indication
appears next to the command, indicating an error condition.
172
 
ErInjSetSCSICommandGenerateError: Enable error injection on a command.
Specify Command Number and Number of Error Commands in the 4th and 6th
parameters. 
See API reference manual (section 5.5.139, page 748).
ErInjSetSCSICommandRepeatedErrorOnCommandNumber
(int nCommand, BOOL bEnable, 
short iCountOfRepeatedErrorsOnCommands): 
nCommand specifies SCSI command. See 6.52 SCSI Command type definition in
the API manual.
bEnable: TRUE means you want repeat error as much as iCountOfRepeatedEr‐
rorsOnCommands.
the Sense Key drop down list box, choose an error type, and then enter values for
ASC and ASCQ in the corresponding text boxes.
Target and Device Emulation
S ierra M6‐2 SAS/SATA Protocol Analyzer User Manual
 

Advertisement

Table of Contents
loading