LeCroy Sierra M6-2 User Manual page 433

Sas/sata protocol analyzer
Table of Contents

Advertisement

Sierra Trainer Generation Commands
Setting
COMINIT Settings
COMINIT_NegLen
COMINIT_IdleLen
COMINIT_BurstLen
COMINIT_NumBursts
COMWAKE Settings
COMWAKE_NegLen
COMWAKE_IdleLen
COMWAKE_BurstLen
COMWAKE_NumBursts
COMSAS Settings
COMSAS_NegLen
COMSAS_IdleLen
COMSAS_BurstLen
COMSAS_NumBursts
       
S ierra M6‐2 SAS/SATA Protocol Analyzer User Manual
Default
Value
Description
800
The number of bursts to send as part of this OOB
type.Each Burst is followed by an Idle. The Burst‐Idle
pairs are repeated the requested number of times,
and then followed by the Negation_length of Idle.
480
Burst time between each OOB idle in OOBIs.During
the specified period, the generator will send
ALIGN(0) at the specified speed.
160
Idle time between each OOB burst in OOBIs.During
the specified period, the generator will keep the line
at electric idle.
6
Negation time at the end of the OOB signal in
OOBIs.During the specified period, the generator will
keep the line at electric idle.
280
The number of bursts to send as part of this OOB
type.Each Burst is followed by an Idle. The Burst‐Idle
pairs are repeated the requested number of times,
and then followed by the Negation_length of Idle.
160
Burst time between each OOB idle in OOBIs.During
the specified period, the generator will send
ALIGN(0) at the specified speed.
160
Idle time between each OOB burst in OOBIs.During
the specified period, the generator will keep the line
at electric idle.
6
Negation time at the end of the OOB signal in
OOBIs.During the specified period, the generator will
keep the line at electric idle.
2400
The number of bursts to send as part of this OOB
type.Each Burst is followed by an Idle. The Burst‐Idle
pairs are repeated the requested number of times,
and then followed by the Negation_length of Idle.
1440
Burst time between each OOB idle in OOBIs.During
the specified period, the generator will send
ALIGN(0) at the specified speed.
160
Idle time between each OOB burst in OOBIs.During
the specified period, the generator will keep the line
at electric idle.
6
Negation time at the end of the OOB signal in
OOBIs.During the specified period, the generator will
keep the line at electric idle.
LeCroy Corporation