Primitive And Frame Definitions; Special Conditions For Frames - LeCroy Sierra M6-2 User Manual

Sas/sata protocol analyzer
Table of Contents

Advertisement

LeCroy Corporation
These commands should be configured either in the Setting.inc file or at the beginning of
the traffic generation file as a global statement.

Primitive and Frame Definitions

Five other Include files are provided that define the most of the known templates for
Primitives and Frames. The five are:
Each of the Frame templates defines header and field structure.
The default value for all Frame fields is zero.

Special Conditions for Frames

There are three conditions about Frames that need to be kept in mind when configuring
Frame generation:
1. Frame delimiters need to agree ‐ At the present time, when defining a Frame, make
2. Data Length Fields can be fixed‐length or variable ‐ By default, data frames are of a
If you replace the asterisk with a value, then the field becomes fixed length.
3. CRC Calculations are calculated unless told otherwise ‐ If the CRC is not explicitly
392
 
PrimitivesDecl.inc
AddressFramesDecl.inc
SSPFramesDecl.inc
SMPFramesDecl.inc
STPFramesDecl.inc
sure that the Frame Prologue and Frame Epilogue agree. Do not mix types. For
example, do not mix a SAS Start of Frame (SOF) with a SAS End of Address Frame
(EOAF).
A SAS SOF should be matched to a SAS EOF. A SAS SOAF should be matched to a SAS
EOAF. If generating SATA traffic, a SATA_SOF should be matched to a SATA_EOF.
At the present time, if you mix different types of prologues and epilogues for any
given Frame, the Frame is ignored.
fixed length. If you want to generate variable length frames, place an asterisk in the
Data definition field in the SSPFramesDecl.inc file: 
Data : *
set in the traffic generation file, the application assumes that you want it and
calculates and displays it in front of the generated frames.
If you provide a CRC value, the application uses that value, even if it is incorrect. This
gives you the option of configuring the generator to create errors.
Primitive and Frame Definitions
S ierra M6‐2 SAS/SATA Protocol Analyzer User Manual
 

Advertisement

Table of Contents
loading