20) Inspection of Oil Level Sensor
1.
Check electrical conductivity between terminals of oil level
sensor.
Check oil level sensor if out of specified range.
This test can be made without removing parts.
To be non conductive if float is at position a.
To be conductive if float is at position b.
21) Inspection of Oil Pump
1.
Measure resistance between terminals, and replace oil
pump if the resistance is out of specified range.
This test can be made without removing parts.
Resistance between terminals : @20˚C (68 ˚F)
1.84 - 2.08 Ω
TLDI 115A 2007
a
b
8