TOHATSU TLDI MD 115A SERIES Service Manual page 294

Table of Contents

Advertisement

9-1-1.
Cooling water inlet is blocked.
9-1-2.
Water pump is faulty.
9-1-3.
Battery is faulty, or two batteries are connected in series.
9-1-4.
Rectifier-regulator is faulty.
TPS malfunctions, wire is not connected or wire harness
9-1-5.
is broken.
9-1-6.
TPS connectors (TPS1 and TPS2) are connected in reverse.
Electric oil pump malfunction, or wire is not connected or
9-1-7.
wire harness is broken.
Remote control cable is installed incorrectly, or remote
9-2-1.
control box is faulty.
10-1-1.
Cooling water inlet is blocked.
10-1-2.
Water pump is faulty.
10-1-3.
Thermostat is faulty.
10-1-4.
Cooling water passage is blocked.
10-1-5.
Battery is faulty.
10-1-6.
Charging coil is faulty.
10-1-7.
Charging coil wiring is broken.
10-1-8.
Battery cable or electrical connection is faulty.
10-1-9.
Rectifier-regulator is faulty.
TPS malfunctions, wire is not connected or wire harness
10-1-10.
is broken.
10-1-11.
Warm up lever was raised to start the engine.
TLDI 115A 2007
Cause
Action to be taken
(Refer to reference value or service data.)
Check.
Check, and repair if necessary. Replace.
Check.
Check, and replace if necessary.
Check, and repair if necessary. Replace.
Connected to normal positions.
Check, and replace if necessary.
Check, and repair if necessary. Replace.
Check, and repair if necessary. Replace.
Air compressor cooling water temp is high
(Cooling water does not come of from water nipple)
Replace.
Check, and replace if necessary.
Check, and repair if necessary.
Check, and replace if necessary.
Check, and repair if necessary. Replace.
Return the lever and try to start the engine again.