11) Inspection of Rectifier Complete

1.
Measure resistance between terminals.
This test can be made without removing parts.
Rectifier Tester Check Table
Red
Red
ON
Red
(0Ω)
ON
Black
(5kΩ)
ON
Black
(5kΩ)
ON
Yellow
(4kΩ)
ON
Yellow
(4kΩ)
ON
Yellow
(4kΩ)
Notes:
1 Use HIOKI HiTESTER MODEL 3030 or equivalent tester for this measurement, and do not use megger or
other instrument.
2 When the tester's pointer moves, the result is "ON", or "OFF" when not. The value enclosed by ( ) is
approximately value measured using 1kΩ range of the tester. Note that the value varies among conditions of
the tester (internal power supply), measurement ranges and models.
3 Disconnect all connections, and measure as an independent unit.
4 This check provides only rough indication, and perfect measurement cannot be made with the tester.
TLDI 115A 2007
"ON" means conductive and "OFF" means no conductivity.
Positive Tester Lead (Red)
Red
Black
ON
OFF
(0Ω)
OFF
ON
(5kΩ)
ON
ON
(5kΩ)
(0Ω)
ON
ON
(4kΩ)
(3kΩ)
ON
ON
(4kΩ)
(3kΩ)
ON
ON
(4kΩ)
(3kΩ)
Black
Yellow
Yellow
OFF
OFF
OFF
OFF
ON
ON
(0Ω)
(3kΩ)
ON
(3kΩ)
ON
(3kΩ)
ON
ON
(3kΩ)
(5kΩ)
ON
ON
(3kΩ)
(5kΩ)
Yellow
Red
Black
Yellow
OFF
OFF
OFF
OFF
ON
ON
(3kΩ)
(3kΩ)
ON
ON
(3kΩ)
(3kΩ)
ON
ON
(5kΩ)
(5kΩ)
ON
(5kΩ)
ON
(5kΩ)
8-9