Service Data
Description
Pump Assembly
Trim Cylinder
Tilt Cylinder
PTT Motor
PTT Solenoid
(UP / DN)
Thermostat
Pump Impeller
Pump Case Liner
Guide Plate
Anode
Propeller Shaft
Drive Shaft
Propeller
Oil Seales
2-16
Item
Relief valve opening pressure
Spool check valve opening pressure
Oil capacity
Recommended oil type
Oil filter
Piston diameter
Piston rod diameter
Stroke
Shock absorber valve opening pressure
Piston diameter
Piston rod diameter
Stroke
Rated timing
Rated voltage
Output
Direction of rotation
Rated voltage
Rated timing
Exciting current
Exciting coil resistance
Opening and closing of thermostat valve
Wear and cracks
Wear
Wear
Corrosion
Damage to bearing
Wear on lip of oil seal
Backlash between bevel gears
Damage to bearing
Shaft runout
Wear on lip of oil seal
Wear, warping, cracking, chipping
Wear, damage
Standard Values
Tilted up : 8.8 - 11.8 MPa (1,281 - 1,707 psi)
        
[90 - 120 kg/㎠]
Tilted down : 3.9 - 7.4 MPa (569 - 1,067 psi)
        
[40 - 75kg/㎠]
Upper chest: 0.24 MPa (34.1 psi) [2.4 kg/㎠]
Lower chest: 0.12 MPa (17.1 psi) [1.2 kg/㎠]
682 ㎤ (23.1 fl.oz)
ATF <DEXRON III>
150 mesh
38.0 mm (1.496 in)
17.8 mm (0.701 in)
96.9 mm (3.815 in)
14.7 - 18.6 MPa (2,134 - 2,703 psi) [150 - 190 kg/㎠]
45.0 mm (1.772 in)
19.0 mm (0.748 in)
157.3 mm (6.193 in)
60 sec.
12 V (DC)
400 W
Forward / Reverse
12V (DC)
60sec
4A or less
4.7 - 5.7Ω
With wax type Pressure Relief Valve (PRV)
Valve start temperature: 60 ℃ (140 ゚F)
Valve full-open temperature: 75 ℃ (167 ゚F) or higher
0.3 mm (0.012 in) or less
<Using both center holes for reference>