Checking, Disassembling And Servicing; Hyraulic Pump; Checking - wsm L503 Workshop Manual

Table of Contents

Advertisement

L3130 · L3430 · L3830 · L4630 · L5030, WSM

4. CHECKING, DISASSEMBLING AND SERVICING

[1] HYRAULIC PUMP

(1) Checking

(A) Pump Test Using Flow-meter
Preparation
1. Open the bonnet (1).
2. Remove the side skirt RH (2).
3. Remove the main delivery pipe (3).
(When reassembling)
• Install the copper washers firmly.
Tightening torque
Main delivery pipe joint bolt
(1) Bonnet
(2) Side Skirt RH
8-S5
HYDRAULIC SYSTEM
49.0 to 68.6 N·m
5.0 to 7.0 kgf·m
36.2 to 50.6 ft-lbs
(3) Main Delivery Pipe
W1012121
KiSC issued 02, 2007 A