L3130 · L3430 · L3830 · L4630 · L5030, WSM
Oil Temperature Sensor Resistance
1. Measure the resistance between the sensor terminals.
2. It is OK if the resistance value approximates to the value shown
in the table below.
3. If the exists a large difference, replace the sensor.
Resistance
Reference value
(1) Oil Temperature Sensor
Proportional Reducing Valve Resistance
1. Measure the resistance between the valve terminals.
2. It is OK if the resistance comes to have shown in the table below.
Resistance
Reference value
Shift Solenoid Resistance
1. Measure the resistance between each connector terminal and
each valve body.
2. It is OK if the resistance comes to have shown in the table below.
Measuring point
Solenoid
Connector terminal
(1) Solenoid 1
(2) Solenoid 2
(3) Solenoid 3
(4) Solenoid 4
(5) Solenoid 5
(Sub- range)
(6) Solenoid 6
(Main range)
A : Connector of Solenoid Side
9-S32
ELECTRICAL SYSTEM
16.4 to 21.1 kΩ at −20°C (−4°F)
1.04 to 1.23 kΩ at 40°C (104°F)
0.15 to 0.16 kΩ at 100°C (212°F)
8 to 9 Ω
Resistance
1
2
3
11 to 15 Ω
4
5
6
W1042316
W1042539
W1042693
KiSC issued 02, 2007 A