L3130 · L3430 · L3830 · L4630 · L5030, WSM
Air Mixing Door Control Cable (Blue Tape)
1. Disconnect the air mixing door control cable (3) from the damper
lever (1) of air conditioner control panel side.
(When reassembling)
• Set the damper lever (1) of the air conditioner unit at MAX HOT
position. Reconnect the cable.
• Move the control to MAX HOT position. Fit the inner cable in
position, and press and fix the outer cable by the cable clip (2) in
the direction of arrow (A) as shown at left.
• Move the temperature control lever several times and finally set
it to MAX HOT position to make sure the damper lever is at HOT
position too.
(1) Damper Lever
(2) Cable Clip
(3) Air Mixing Door Control Cable
Mode Door Control Cable (Yellow Tape)
1. Disconnect the air conditioner mode door control cable (3) from
the defrosting (DEF) position control lever (1) of control panel
side.
(When reassembling)
• Set the air conditioner unit to DEF mode position and reconnect
the cable (3).
• Set the control at DEF position. Fit the inner cable in position,
and press and fix the outer cable by the cable clip (2) in the
direction of arrow (A) as shown at left.
• Move the mode lever several times and finally set it to DEF
position to make sure to air conditioner unit is at defrosting (DEF)
mode position.
• Lay and fix the mode door control cable over the water valve
cable.
(1) DEF. Control Lever
(2) Cable Clip
(3) Mode Door Control Cable
10-S46
a : 5 to 10 mm (0.20 to 0.40 in.)
A : Direction of Pulling Outer Cable
W1035584
a : 5 to 10 mm (0.20 to 0.40 in.)
A : Direction of Pulling Outer Cable
W1035795
KiSC issued 02, 2007 A