Check Points Of Every 100 Hours - wsm L503 Workshop Manual

Table of Contents

Advertisement

L3130 · L3430 · L3830 · L4630 · L5030, WSM

[4] CHECK POINTS OF EVERY 100 HOURS

Changing Engine Oil
1. See page G-15.
Adjusting Brake Pedal
1. See page G-18.
Cleaning Air Cleaner Primary Element
1. Remove the air cleaner cover and primary element.
2. Clean the primary element :
- When dry dust adheres to the element, blow compressed air
from the inside turning the element. Pressure of compressed
air must be under 205 kPa (2.1 kgf/cm
- When carbon or oil adheres to the element, soak the element
in detergent for 15 minutes then wash it several times in water,
rinse with clean water and dry it naturally. After element is fully
dried, inspect inside of the element with a light and check if it is
damaged or not.
3. Replace air cleaner primary element :
Once yearly or after every six times of cleaning, whichever
comes first.
NOTE
• Check to see if the evacuator valve is blocked with dust.
IMPORTANT
• The air cleaner uses a dry element, never apply oil.
• Do not run the engine with filter element removed.
• Be sure to refit the cover with the arrow ↑ (on the rear of
cover) upright. If the cover is improperly fitted, evacuator
valve will not function and dust will adhere to the element.
• Do not touch the secondary element except in cases where
replacing is required.
See "Replacing Air Cleaner Secondary Element" in Every 1
Year section. (See page G-32.)
Evacuator Valve
Open the evacuator valve (4) once a week under ordinary
conditions or daily when used in a dusty place to get rid of large
particles of dust and dirt.
(1) Secondary (Safety) Element
(2) Primary Element
G-22
G GENERAL
W10320350
W1075566
2
, 30 psi).
(3) Cover
(4) Evacuator Valve
W1076669
KiSC issued 02, 2007 A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L4630L3830L3430L3130L5030L3400