wsm L503 Workshop Manual page 605

Table of Contents

Advertisement

L3130 · L3430 · L3830 · L4630 · L5030, WSM
Blower Motor and Blower Resistor
1. Remove the outer roof.
2. Disconnect the battery negative cable.
3. Disconnect the A/C blower motor connector (1).
4. Disconnect the A/C blower resistor connector (2) for A/C blower
resistor (3).
(1) A/C Blower Motor Connector
(2) A/C Blower Resistor Connector
Water Valve Control Cable (White Tape)
1. When disconnecting the water valve cable (1), follow the next
reassembly procedure.
(When reassembling)
• Fully close the water valve (3) and reconnect the cable (1).
• Set the control at MAX COOL position. Fit the inner cable in
position, and press and fix the outer cable by the cable clip (2) in
the direction of arrow (A) as shown at left.
• Move the temperature control lever several times to make sure
the water valve is fully closed at MAX COOL position.
• Do not allow the water valve cable to bend just away from the
control, nor to get caught by the outer roof.
(1) Water Valve Control Cable
(2) Cable Clip
(3) Water Valve
10-S39
(3) A/C Blower Resistor
W1023280
a : 5 to 10 mm (0.20 to 0.40 in.)
A : Direction of Pulling Outer Cable
W1023983
KiSC issued 02, 2007 A