wsm L503 Workshop Manual page 446

Table of Contents

Advertisement

L3130 · L3430 · L3830 · L4630 · L5030, WSM
Hydraulic Flow Test
IMPORTANT
• When using a flowmeter other than KUBOTA specified
flowmeter, be sure to use the instructions with that
flowmeter.
• Do not close the flowmeter loading valve completely, before
testing, because it has no relief valve.
1. Install the pump adaptor (see page G-54) with O-ring to the pump
discharge port.
2. Connect the hydraulic test hose to the adaptor and flowmeter
inlet port.
3. Connect the other hydraulic test hose to the flowmeter outlet port
and to transmission fluid filling plug hole.
4. Open the flowmeter loading valve completely.
counterclockwises.)
5. Start the engine and set the engine speed at 2000 to 2200
−1
min
(rpm).
6. Slowly close the loading valve to generate pressure approx. 14.7
2
MPa (150 kgf/cm
, 2133 psi). Hold in this condition until oil
temperature reached approx. 40 °C (104 °F)
7. Open the loading valve completely.
8. Set the engine speed. (Refer to Condition.)
9. Read and note the pump delivery at no pressure.
10.Slowly close the loading valve to increase (Rated pressure). As
the load is increased, engine speed drops, therefore, reset the
engine speed.
11.Read and note the pump delivery at rated pressure.
12.Open the loading valve completely and stop the engine.
13.If the pump delivery does not reach the allowable limit, check the
pump suction line, oil filter or hydraulic pump.
Condition
• Engine Speed.....Approx. 2700 min
• Rated pressure
L3130, L3430, L3830 .... 17.1 to 18.1 MPa
L4630, L5030 ................ 18.1 to 19.1 MPa
• Oil Temperature ............ 40 to 60 °C
A : Manual and Glide Shift
Transmission
8-S6
HYDRAULIC SYSTEM
−1
(rpm)
2
174.4 to 184.6 kgf/cm
2480 to 2625 psi
2
184.6 to 194.8 kgf/cm
2625 to 2770 psi
104 to 140 °F
B : Hydrostatic Transmission
(Turn
W10187910