G75: Optional Skip - Omron C200H-MC221 Operation Manual

Motion control unit
Hide thumbs Also See for C200H-MC221:
Table of Contents

Advertisement

G Functions

5-5-26 G75: OPTIONAL SKIP

Format
Parameters
Description
Example Program
Speed
Optional
input 3
Speed
Optional
input 3
Skips the next block when the specified optional input is ON.
G75j<optional number>
The following table shows the possible settings for the parameters.
Parameter
Optional number
If the specified input is ON when this function is executed, the next block will be
skipped. The source of the optional input depends on the optional number speci-
fied, as shown below.
0 through 4:
5 and 6:
Program execution will continue normally if the optional input comes ON while
the next block is being executed. The OPTIONAL SKIP function is ineffective if
the following block contains a SUBPROGRAM END function (G73) or PRO-
GRAM END function (G79).
:
:
N008
G11
N009
G91
N010
G01
X50
N011
G75
3
N012
G01
X50
N013
G01
X50
:
:
(Operation when the optional input isn't ON)
(Low level)
(Operation when the optional input is ON)
When block N008 contains the pass mode function (G10), blocks N011 and
N012 are pre-executed while N010 is being executed, so block N012 won't be
skipped if optional input 3 is turned ON after execution of block N010.
00 to 06
Inputs from the PC's data area interface
Inputs from general inputs 1 and 2
Section 5-5
Possible settings
Time
Time
103