Omron C200H-MC221 Operation Manual page 281

Motion control unit
Hide thumbs Also See for C200H-MC221:
Table of Contents

Advertisement

Additional Origin Search Patterns
One Direction-mode Origin Searches 10
These origin searches are performed with an origin proximity switch and the initial search direction set to CW, but
no Z-phase signal.
Limit switches
Origin proximity
switch
Z-phase signal
Speed
CCW
Appendix B
CW
Error
(No origin proximity signal)
Error
(No origin proximity signal)
Error
(No origin proximity signal)
Error
(Overtravel always ON.)
Error
(Origin proximity and overtravel
simultaneously ON.)
Error
(Overtravel always ON.)
261