Example Program
Starting point

5-5-6 G11: STOP MODE

Format
Parameters
Description
1, 2, 3...
84
:
:
N010
G00
X30
N011
G10
N012
G01
X70
N013
G01
Y90
N014
G01
X120
N015
G00
Y30
N016
G00
X150
:
:
Switches the operating mode to stop mode.
G11
None
This function switches the operating mode to stop mode. If this function is
executed, subsequent interpolation (linear or circular) functions will be deceler-
ated to a stop at the end point, an in-position check will be performed, and then
the next positioning operation will be performed after completion of the position-
ing is verified.
The stop mode is valid until one of the following functions is executed:
1. The PASS MODE function (G10)
2. The REFERENCE ORIGIN RETURN function (G26)
3. The WORKPIECE ORIGIN RETURN function (G27)
4. The ORIGIN SEARCH function (G28)
A reset will be performed and the operating mode will be switched to pass mode
when a REFERENCE ORIGIN RETURN (G26), WORKPIECE ORIGIN
RETURN (G27), or ORIGIN SEARCH (G28) function is executed. Refer to 5-7
Mode Transitions Caused by G Functions for details on modes when resetting.
Y30
The next operation is performed
without decelerating to a stop.
End point
Section 5-5

Hide quick links: