Word N+1 Bit 14: Error Reset Bit (All Tasks) - Omron C200H-MC221 Operation Manual

Motion control unit
Hide thumbs Also See for C200H-MC221:
Table of Contents

Advertisement

Interface Bit Specifics
Timing Chart
Program Example

6-5-14 Word n+1 Bit 14: Error Reset Bit (All Tasks)

Signal
Timing Chart
146
Flash Memory Write Bit
(n+1 bit 13)
Flash Memory Write
Completed Flag
(n+8 bit 10)
Execution condition
R1
n+8 10
Flash Memory Write
Completed Flag
n+1 13
Flash Memory Write Bit
The error of the MC Unit will be reset when this bit is turned ON.
This bit must be on hold until the Error Flag is turned OFF.
When the Error Flag is turned OFF, error type data will be turned OFF as well.
The Error Reset settings have the following functions.
Signal
Resets MC Unit error.
Error reset (n+1 bit 14)
Error Flag (n+8 bit 14)
Error type data
(n+8 bits 00 to 04)
Error code (n+9)
2 s min.
20 ms min.
DIFU(13)
n+1
13
Function
20 ms
min.
XXXX
Another error during this period will
not turn the bit ON until the Error
Reset Bit is turned OFF.
Section 6-5
Work bit
R1
OUT
(Flash
Memory
Write Bit)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents