G Functions
92
3. A general input is turned ON while the axis is being accelerated. (2)
Specified
speed 1
Specified
speed 2
4. A general input is turned ON while the axis is being accelerated. (3)
General input ON
Specified
speed 1
Specified
speed 2
5. A general input is turned ON when the axis is being accelerated. (4)
Specified
speed 1
Specified
speed 2
Supplementary Information
When positioning using INTERRUPT INCHING, positions that are determined
after external sensors become valid will vary depending on various conditions
such as an ambient temperature. This is caused by a delay in sensing by exter-
nal sensors and the general input circuit of the MC Unit.
Shown below is a description of the MC Unit's sensing delay assuming there is
no sensing delay due to external sensors.
External sensor
General input
• The external sensor changes from invalid to valid.
General input ON
General input ON
The axis is decelerated sharply
because the movement of the axis is
small and the speed of the axis is high.
Invalid
Valid
T: Sensing delay
T
OFF
ON
Speed
Position
control
control
Positioning to be started by the MC Unit.