Word N+8 Bit 06: Transmission Completion Flag; Word N+8 Bit 07: Data Transmission Error Flag - Omron C200H-MC221 Operation Manual

Motion control unit
Hide thumbs Also See for C200H-MC221:
Table of Contents

Advertisement

Interface Bit Specifics
Signal
Timing Chart
Program Example

6-5-31 Word n+8 Bit 06: Transmission Completion Flag

Signal

6-5-32 Word n+8 Bit 07: Data Transmission Error Flag

The Driver Alarm Reset Bit settings have the following functions.
Signal
1 (ON)
The override data is valid.
0 (OFF)
The override data is invalid.
Jogging Bit
(n+5 bit 03)
Jog Direction Bit
(n+5 bit 13)
Override Setting Bit
(n+5 bit 12)
Override setting
(n+4)
Setting condition
Jog Direction
condition
Jogging condition
This flag will be turned ON regardless of whether data has been transmitted nor-
mally or not.
This flag is used for the timing to turn the Transmission Control Bit ON.
This flag will not turn OFF until the Transmission Control Bit is turned OFF.
No data can be transmitted while this flag is ON.
The Transmission Completion Flag settings have the following meanings.
Signal
Data has been transmitted.
No data is being written.
Note Refer to 6-5-11 Word n+1 Bit 11: Transmission Control Bit.
This flag will be turned ON when one of the following errors results during data
transmission.
• The number of transfer words, source word, or destination address is not in
BCD.
Function
500
Jogging performed with the set override value (50.0%).
Sets the override
data. (n+4)
Function
Section 6-5
OUT
(Sets the
n+5
override
12
value.)
OUT
(Sets the jog-
n+5
13
ging direc-
tion.)
OUT
n+5
(Starts the
03
jogging.)