Origin Search Patterns
7-4-6 One Direction-mode Origin Searches 1
CCW
Limit switches
Origin proximity
switch
Z-phase signal
Speed
7-4-7 One Direction-mode Origin Searches 2
Limit switches
Origin proximity switch
Z-phase signal
Speed
These origin searches are performed with an origin proximity switch and the ini-
tial search direction set to CW.
These origin searches are performed with an origin proximity switch and the ini-
tial search direction set to CW.
CCW
Section 7-4
CW
Error
(No origin proximity signal)
Error
(Overtravel always ON.)
CW
185