Setting the DIP Switch

1-4

Setting the DIP Switch

DIP Switch Settings
4
It may be necessary to set the DIP switch when using the Teaching Box. The DIP
switch is on the rear panel of the MC Unit.
Pin 2 of the DIP switch controls the language displayed on the Teaching Box, as
shown in the following table.
Pin
Setting
1
OFF
Enables the initial setting and soft reset function of the absolute
encoder (the factory setting).
ON
Disables the initial setting and soft reset function of the absolute
encoder (the factory setting).
2
OFF
The Teaching Box will display Japanese text.
ON
The Teaching Box will display English text (factory setting).
3 to 4
---
Leave these pins set to OFF (factory settings).
The pin 1 setting will be ignored when using an incremental encoder.
Note
1. Use the interface relay for the initial setting and soft reset setting of the abso-
lute encoder. Refer to Section 6-5 Interface Bit Specifics.
2. For setting the absolute encoder from the Teaching Box, refer to 7-6 Setting
Up the Absolute Encoder and 7-7 ABS Soft Reset.
3. The Teaching Box display language selector (pin 2) is referenced only when
the PC is turned ON.