I/O Connector
Connection Example
Terminal
no.
10
The following diagram shows an example connection for just the X axis. Connect
Y-axis wires in the same way.
Label
Normally closed
Common
Common
Common
Emergency
stop input
Common
Common
Common
Note OUT1 or OUT2 of the Terminals is not available for the C200H-MC221.
CCW limit
Origin
input
proximity
input
+24 V
DC
power
0 V
supply
Section 2-1
Normally open
CW limit
input