Omron C200H-MC221 Operation Manual page 250

Motion control unit
Hide thumbs Also See for C200H-MC221:
Table of Contents

Advertisement

Control Bit/Flag Timing Charts
16. Automatic/Manual Mode Bit, Cycle Start Bit, and Forced Block End Bit
Automatic/Manual Mode Bit
Cycle Start Bit
Forced Block End Bit
Operation
Program execution is stopped by the Forced Block End Bit. The Unit is switched to manual mode when the Auto-
matic/Manual Mode Bit is turned OFF.
17. Cycle Start Bit, Single Block Bit, and Forced Block End Bit
Cycle Start Bit
Single Block Bit
Forced Block End Bit
Operation
Program execution is started with the Single Block Bit ON, but execution of block N001 is stopped by the Forced
Block End Bit. The next block is executed when the Cycle Start Bit is turned ON again.
18. Cycle Start Bit and M Code Reset Bit
Program execution is started by the Cycle Start Bit. The next operation (G01) is executed without outputting M
code 100 because the M Code Reset Bit is ON.
19. Cycle Start Bit and M Code Reset Bit
The Cycle Start Bit is invalid while the Unit is waiting for an M code reset. When the M Code Reset BIt is turned OFF,
the standby status is cleared and the status of the Cycle Start Bit is checked. The Cycle Start Bit is ON, so program
execution is restarted.
230
Cycle Start Bit
M Code Reset Bit
Operation
Cycle Start Bit
M Code Reset Bit
Operation
Appendix A