STW34, STW37, STW40, WSM
1. TROUBLESHOOTING
Symptom
Stator Motor Does
not Operate
Probable Cause and
Checking Procedure
1. Battery is discharged.
2. Battery is damaged.
3. Slow blow fuse is blown.
4. PTO control switch is
engaged.
5. Safety switch (clutch pedal
and HST) is damaged.
6. Seat switch is damaged.
7. Rear PTO switch is
damaged.
8. Mid PTO switch is
damaged.
9. OPC controller is
damaged.
10.Main switch is damaged.
11.Starter motor is damaged.
Solution
Recharge battery.
Replace battery.
Replace slow blow fuse.
Disengage PTO control switch.
Replace or adjust safety switch.
Replace seat
Replace or adjust rear PTO switch
Replace or adjust mid PTO switch
Replace OPC controller
Replace main switch
Replace or repair starter motor.
1-S1
ENGINE
Reference
Page
G-29
–
G-38
–
9-S26
9-S26
9-S39
9-S39
9-S30
9-S12,
9-S14
9-S25
KiSC issued 11, 2014 A