STW34, STW37, STW40, WSM
Wiring Harness
1. Disconnect the combination switch connector (5), main switch
connector (1), hazard switch connector (4) and wiper motor
connector (2).
2. Remove the panel under cover (3).
3. Remove the rubbers (6), (7).
4. Turn over the fuel level sensor cover (8).
5. Disconnect the grounding wire (10) and 1P connector (9) from
the fuel level sensor.
(1) Main Switch Connector
(2) Wiper Motor Connector
(3) Panel Under Cover
(4) Hazard Switch Connector
(5) Combination Switch Connector
2-S18
CLUTCH
(6) Rubber
(7) Rubber
(8) Fuel Level Sensor Cover
(9) 1P Connector
(10) Grounding Wire
9Y1211109ENS0041US0