STW34, STW37, STW40, WSM
Adjusting Position Control Lever Operating Force
1. Set a spring balance to the position control lever (1) to measure
the operating force.
2. If the measurement is not within the factory specification, loosen
the lock nut (3) and adjust the operating force with position
control lever mounting nut (2).
(When reassembling)
• Be sure to tight the lock nut.
Position control lever
Factory specification
operating force
(1) Position Control Lever
(2) Mounting Nut
8-S13
HYDRAULIC SYSTEM
20 to 50 N
2.1 to 5.0 kgf
4.5 to 11 lbf
(3) Lock Nut
9Y1211109HYS0013US0
KiSC issued 11, 2014 A