Blower Motor; Temperature Motor - wsm STW37 Workshop Manual

Table of Contents

Advertisement

STW34, STW37, STW40, WSM

(4) Blower Motor

(5) Temperature Motor

Blower Motor Test
1. Remove the outer roof.
2. Turn the blower motor (1) by hand and check whether it turns
smoothly.
3. Disconnect the 2P connector (2) of blower motor (1).
4. Connect a jumper lead from battery (3) positive terminal to
connector terminal b.
5. Connect a jumper lead from battery negative terminal to
connector terminal e momentarily.
6. If the blower motor does not run, check the motor.
(1) Blower Motor
(2) 2P Connector (Blower Motor Side)
(3) Battery (12 V)
Temperature Motor Checking
1. Make sure whether the temperature control dial (2) is damaged.
(See page 10-S26.)
2. Turn the main switch to "ON" position.
3. Turn the blower switch (3) at 1 position.
4. Turn the temperature control dial from "COOL" position (A) to
"WARM" position (B). At the time, make sure the motor is
operating.
5. If the motor does not operate, replace it.
(1) Temperature Motor
(2) Temperature Control Dial
(3) Blower Switch
10-S27
b:
Terminal b
e:
Terminal e
9Y1211109CAS0043US0
(A) COOL
(B) WARM
9Y1211109CAS0044US0
KiSC issued 11, 2014 A