STW34, STW37, STW40, WSM
High Pressure Hose 1, 2 and Low Pressure Hose
1. Disconnect the low pressure hose (3) and high pressure hose 1
(1) from the compressor (2), then cap the open fittings
immediately to keep moisture out of the system.
2. Slide the condenser (4).
3. Disconnect the high pressure hose 1 (1) from the condenser (4)
and cap the place immediately which disconnected pressure
hose to keep moisture out of the system.
4. Disconnect the high pressure hose 2 (6) from the receiver (5)
and cap the place immediately which disconnected pressure
hose to keep moisture out of the system.
(When reassembling)
• Apply compressor oil (DENSO CO. ND-OIL8) to the O-rings and
be careful not to damage them.
Low pressure hose
mounting screw
(compressor side)
High pressure hose 1
mounting screw
(compressor side)
High pressure hose 1
Tightening torque
mounting screw
(condenser side)
High pressure hose 2
mounting screw
(receiver side)
High pressure hose 2
mounting screw
(condenser side)
(1) High Pressure Hose 1
(2) Compressor
(3) Low Pressure Hose
10-S49
7.85 to 11.8 N·m
0.801 to 1.20 kgf·m
5.79 to 8.70 lbf·ft
7.85 to 11.8 N·m
0.801 to 1.20 kgf·m
5.79 to 8.70 lbf·ft
3.9 to 6.8 N·m
0.40 to 0.69 kgf·m
2.9 to 5.0 lbf·ft
3.9 to 6.8 N·m
0.40 to 0.69 kgf·m
2.9 to 5.0 lbf·ft
3.9 to 6.8 N·m
0.40 to 0.69 kgf·m
2.9 to 5.0 lbf·ft
(4) Condenser
(5) Receiver
(6) High Pressure Hose 2
9Y1211109CAS0067US0
KiSC issued 11, 2014 A
CABIN