STW34, STW37, STW40, WSM
Grow Relay (For ROPS)
1. Turn the main switch off and remove the glow relay (1).
2. Apply battery voltage across 3 and 4 terminals, and check for
continuity across 1 and 2 terminals.
3. If continuity is not established across 1 and 2 terminals, renew
the glow relay.
NOTE
• The glow relay and the key stop relay are the same parts.
Resistance
Terminal 1 – Terminal 2
(1) Glow Relay
Electrical Outlet Relay (For Cabin)
1. Turn the main switch off and remove the electrical outlet relay
(1).
2. Apply battery voltage across 3 and 4 terminals, and check for
continuity across 1 and 2 terminals.
3. If continuity is not established across 1 and 2 terminals, renew
the glow relay.
NOTE
• The electrical outlet relay and the key stop relay are the
same parts.
Resistance
Terminal 1 – Terminal 2
(1) Electrical Outlet Relay
9-S28
ELECTRICAL SYSTEM
0 Ω
9Y1211109ELS0042US0
0 Ω
9Y1211109ELS0043US0