Field
Description
Sampling Rate
The statistical sampling rate for packet sampling from this source. A sampling rate of 1
counts all packets. A value of zero (0) disables sampling. A value of N means that out of N
incoming packets, 1 packet will be sampled. The range is 1024-65536 and 0. The default
is 0.
no sflow sampler
Use this command to reset the sFlow sampler instance to the default settings.
Format
no sflow sampler {<rcvr-indx> | rate <sampling-rate> | maxheadersize
<size>}
Mode
Interface Config

sflow poller

A data source configured to collect counter samples is called a poller. Use this command to enable
a new sFlow poller instance for this data source if <rcvr_idx> is valid.
Format
sflow poller {<rcvr-indx> | interval <poll-interval>}
Mode
Interface Config
Field
Description
Receiver Index
Enter the sFlow Receiver associated with the sampler/poller. A value of zero (0) means
that no receiver is configured. The range is 1-8. The default is 0.
Poll Interval
Enter the sFlow instance polling interval. A poll interval of zero (0) disables counter
sampling. When set to zero (0), all the poller parameters are set to their corresponding
default value. The range is 0-86400. The default is 0. A value of N means once in N
seconds a counter sample is generated.
no sflow poller
Use this command to reset the sFlow poller instance to the default settings.