Canon imageRUNNER ADVANCE C5255 Series Service Manual page 911

Hide thumbs Also See for imageRUNNER ADVANCE C5255 Series:
Table of Contents

Advertisement

COPIER > ADJUST > DENS
DMLMT-HK
Adj Bk-clr charge DC voltage upper limit
Lv.2 Details
To adjust the offset of the charging DC voltage upper limit for Bk in
D-max control.
Use case
When a failure occurs due to limiter of D-max control
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Execute quick adjustment of auto gradation adjustment.
Caution
Do not use this at the normal service.
Display/adj/set range
-300 to 300
Unit
V
Default value
0
Related service mode
COPIER>ADJUST>DENS>DMLMT-LK
DMLMT-LY
Adj Y-clr charge DC voltage lower limit
Lv.2 Details
To adjust the offset of the charging DC voltage lower limit for Y in
D-max control.
Use case
When a failure occurs due to limiter of D-max control
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Execute quick adjustment of auto gradation adjustment.
Caution
Do not use this at the normal service.
Display/adj/set range
-300 to 300
Unit
V
Default value
0
Related service mode
COPIER>ADJUST>DENS>DMLMT-HY
DMLMT-LM
Adj M-clr charge DC voltage lower limit
Lv.2 Details
To adjust the offset of the charging DC voltage lower limit for M in
D-max control.
Use case
When a failure occurs due to limiter of D-max control
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Execute quick adjustment of auto gradation adjustment.
Caution
Do not use this at the normal service.
Display/adj/set range
-300 to 300
Unit
V
Default value
0
Related service mode
COPIER>ADJUST>DENS>DMLMT-HM
8
Service Mode > COPIER > ADJUST > DENS
8
Service Mode > COPIER > ADJUST > DENS
COPIER > ADJUST > DENS
DMLMT-LC
Adj C-clr charge DC voltage lower limit
Lv.2 Details
To adjust the offset of the charging DC voltage lower limit for C in
D-max control.
Use case
When a failure occurs due to limiter of D-max control
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Execute quick adjustment of auto gradation adjustment.
Caution
Do not use this at the normal service.
Display/adj/set range
-300 to 300
Unit
V
Default value
0
Related service mode
COPIER>ADJUST>DENS>DMLMT-HC
DMLMT-LK
Adj Bk-clr charge DC voltage lower limit
Lv.2 Details
To adjust the offset of the charging DC voltage lower limit for Bk in
D-max control.
Use case
When a failure occurs due to limiter of D-max control
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Execute quick adjustment of auto gradation adjustment.
Caution
Do not use this at the normal service.
Display/adj/set range
-300 to 300
Unit
V
Default value
0
Related service mode
COPIER>ADJUST>DENS>DMLMT-HK
CONT-Y
ATR Sensor (Y) control voltage entry
Lv.1 Details
To enter the density detection control voltage of the ATR Sensor (Y).
When replacing the DC Controller PCB/clearing RAM data, enter the
value of service label.
Use case
When the backup data is cleared by RAM clear, etc.
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
After the setting value is changed, write the changed value in the
service label.
Display/adj/set range
0 to 255
Unit
V
CONT-M
ATR Sensor (M) control voltage entry
Lv.1 Details
To enter the density detection control voltage of the ATR Sensor (M).
When replacing the DC Controller PCB/clearing RAM data, enter the
value of service label.
Use case
When the backup data is cleared by RAM clear, etc.
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
After the setting value is changed, write the changed value in the
service label.
Display/adj/set range
0 to 255
Unit
V
8-91